The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique
Abstract
The fabrication and performance of a miniature optically pumped atomic magnetometer constructed with microfabricated components are discussed. This device measures the spin precession frequency of Rb87 atoms to determine the magnetic field by use of the Mx technique. It has a demonstrated sensitivity to magnetic fields of 5pT∕Hz1∕2 for a bandwidth from 1to100Hz, nearly an order of magnitude improvement over our previous chip-scale magnetometer. The 3dB bandwidth has also been increased to 1kHz by reconfiguring the miniature vapor cell heater.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Operation of the Rubidium Vapor Magnetometer
Bloom, A. L. (1962) · Applied Optics · doi:10.1364/ao.1.000061 · Cited by 282
Cited by
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Self-citationSubpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
Self-citationMulti-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Self-citationZhang, R., Mhaskar, R., Smith, K., & Prouty, M. (2020) · Applied Physics Letters · doi:10.1063/5.0004746 · Cited by 48
Metadata
- Authors
- Schwindt, P. D. D., Lindseth, B., Knappe, S., Shah, V., Kitching, J., & Liew, L.-A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2007-02-19
- Volume
- 90
- Issue
- 8
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2048135055
- Cited by
- 183
- References
- 1
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.