The DOI matches its Crossref record; 119 of the 119 references it cites were found in a registry or an index.
Chip-scale atomic devices
Open accessAbstract
Chip-scale atomic devices combine elements of precision atomic spectroscopy, silicon micromachining, and advanced diode laser technology to create compact, low-power, and manufacturable instruments with high precision and stability. Microfabricated alkali vapor cells are at the heart of most of these technologies, and the fabrication of these cells is discussed in detail. We review the design, fabrication, and performance of chip-scale atomic clocks, magnetometers, and gyroscopes and discuss many applications in which these novel instruments are being used. Finally, we present prospects for future generations of miniaturized devices, such as photonically integrated systems and manufacturable devices, which may enable embedded absolute measurement of a broad range of physical quantities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of the linewidth of semiconductor lasers
Henry, C. (1982) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1982.1071522 · Cited by 2,488
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
HAPPER, W. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.169 · Cited by 1,710
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Single spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,444
V Coherent Population Trapping in Laser Spectroscopy
Arimondo, E. (1996) · Progress in Optics · doi:10.1016/s0079-6638(08)70531-6 · Cited by 1,158
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Cited by
Sensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
Taking atom interferometric quantum sensors from the laboratory to real-world applications
Bongs, K., Holynski, M., Vovrosh, J., Bouyer, P., Condon, G., Rasel, E., Schubert, C., Schleich, W. P., & Roura, A. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0117-4 · Cited by 382
Zhang, R., Mhaskar, R., Smith, K., & Prouty, M. (2020) · Applied Physics Letters · doi:10.1063/5.0004746 · Cited by 48
Suppression of current source noise with an atomic magnetometer
Shen, L., Zhang, R., Wu, T., Peng, X., Yu, S., Chen, J., & Guo, H. (2020) · Review of Scientific Instruments · doi:10.1063/5.0009987 · Cited by 16
Metadata
- Authors
- Kitching, J.
- Venue
- Applied Physics Reviews
- Publisher
- AIP Publishing
- Published
- 2018-09
- Volume
- 5
- Issue
- 3
- Pages
- 031302
- ISSN
- 1931-9401 (ISSN-L)
- OpenAlex
- W1626206720
- Cited by
- 621
- References
- 119
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chip-scale atomic devices. https://app.cochat.ai/papers/10.1063/1.5026238
- The paper
- Kitching, J. (2018). Chip-scale atomic devices. Applied Physics Reviews. https://doi.org/10.1063/1.5026238
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.