The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Enhancement of sensitivity in gas chemiresistors based on carbon nanotube surface functionalized with noble metal (Au, Pt) nanoclusters
Abstract
Multiwalled carbon nanotube (MWCNT) films have been fabricated by using plasma-enhanced chemical vapor deposition system onto Cr–Au patterned alumina substrates, provided with 3nm thick Fe growth catalyst, for NO2 and NH3 gas sensing applications, at sensor temperature in the range of 100–250°C. Nanoclusters of noble metal surface catalysts (Au and Pt) have been sputtered on the surface of MWCNTs to enhance the gas sensitivity with respect to unfunctionalized carbon nanotube films. It was found that the gas sensitivity of Pt- and Au-functionalized MWCNT gas sensors significantly improved by a factor up to an order of magnitude through a spillover effect for NH3 and NO2 gas detections, respectively. The metal-functionalized MWCNT sensors exhibit very high gas sensitivity, fast response, reversibility, good repeatability, and sub-ppm range detection limit with the sensing properties of the MWCNT films tailored by surface catalyst used to functionalize the MWCNT sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Cited by
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Gas sensors using carbon nanomaterials: A review
Llobet, E. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.11.014 · Cited by 692
Jeong, S., Kim, J., & Lee, J. (2020) · Advanced Materials · doi:10.1002/adma.202002075 · Cited by 415
Graphene-based nitrogen dioxide gas sensors
Ko, G., Kim, H.-Y., Ahn, J., Park, Y.-M., Lee, K.-Y., & Kim, J. (2010) · Current Applied Physics · doi:10.1016/j.cap.2009.12.024 · Cited by 336
Designer carbon nanotubes for contaminant removal in water and wastewater: A critical review
Sarkar, B., Mandal, S., Tsang, Y. F., Kumar, P., Kim, K.-H., & Ok, Y. S. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.08.132 · Cited by 314
Lu, G., Ocola, L. E., & Chen, J. (2009) · Advanced Materials · doi:10.1002/adma.200803536 · Cited by 306
Recent advances in carbon material-based NO2 gas sensors
Lee, S. W., Lee, W., Hong, Y., Lee, G., & Yoon, D. S. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.08.203 · Cited by 304
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Nanowire Chemical/Biological Sensors: Status and a Roadmap for the Future
Fennell, J. F., Liu, S. F., Azzarelli, J. M., Weis, J. G., Rochat, S., Mirica, K. A., Ravnsbæk, J. B., & Swager, T. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201505308 · Cited by 274
Metadata
- Authors
- Penza, M., Cassano, G., Rossi, R., Alvisi, M., Rizzo, A., Signore, M. A., Dikonimos, T., Serra, E., & Giorgi, R.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2007-04-23
- Volume
- 90
- Issue
- 17
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1977750593
- Cited by
- 167
- References
- 2
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.