The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors
Abstract
Ultrasensitive, label-free, and real-time prostate-specific antigen (PSA) sensor was developed using n-type silicon nanowire-based structures configured as field-effect transistors using the conventional “top-down” semiconductor processes. Specific binding of PSA with antibody of PSA (anti-PSA) immobilized on the Si surface through covalent linkage leads to a conductivity change in response to variations of electric field at the surface. The conductance changes depending on PSA concentrations and pH values in solution according to isoelectric point of PSA provide the evidence of the real-time detection of 1fg∕ml PSA. The authors also explored the sensitivity of PSA immunodetection depending on both Si–field-effect transistors (FET) dimensions and doping concentrations to provide strategy for fabrication of an ultrasensitive Si-FET biosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Cited by
Mani, V., Chikkaveeraiah, B. V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800863w · Cited by 532
Label-free DNA detection with a nanogap embedded complementary metal oxide semiconductor
Kim, C.-H., Jung, C., Lee, K.-B., Park, H. G., & Choi, Y.-K. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/13/135502 · Cited by 103
Shalev, G., Landman, G., Amit, I., Rosenwaks, Y., & Levy, I. (2013) · NPG Asia Materials · doi:10.1038/am.2012.75 · Cited by 61
Kumar, S., Singh, B., & Singh, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3056385 · Cited by 39
Metadata
- Authors
- Kim, A., Ah, C. S., Yu, H. Y., Yang, J.-H., Baek, I.-B., Ahn, C.-G., Park, C. W., Jun, M. S., & Lee, S.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2007-09-03
- Volume
- 91
- Issue
- 10
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2068235344
- Cited by
- 250
- References
- 1
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors. https://app.cochat.ai/papers/10.1063/1.2779965
- The paper
- Kim, A., Ah, C. S., Yu, H. Y., Yang, J.-H., Baek, I.-B., Ahn, C.-G., Park, C. W., Jun, M. S., & Lee, S. (2007). Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors. Applied Physics Letters. https://doi.org/10.1063/1.2779965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.