The DOI matches its Crossref record.
High-time-resolution pump-probe system with broadband detection for the study of time-domain vibrational dynamics
Abstract
We present an ultrafast transient absorption spectroscopy system in the visible combining high-sensitivity broadband detection with extreme temporal resolution. The instrument is based on an ultrabroadband sub-10fs optical parametric amplifier coupled to an optical multichannel analyzer with fast electronics, enabling single-shot detection at 1kHz repetition rate. For a given pump-probe delay τ, we achieve a differential transmission (ΔT∕T) sensitivity of the order of 10−4 over the λpr=490–720nm probe wavelength range by averaging over 1000 shots, allowing the acquisition of complete two-dimensional ΔT∕T (λpr,τ) maps within a few minute measurement time. We present application examples highlighting the capability of this instrument to observe ultrafast dynamical processes, follow impulsively excited vibrational motions with frequency as high as 3000cm−1 (11fs period), and determine the probe wavelength dependence of amplitude and phase of the oscillations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conical intersection dynamics of the primary photoisomerization event in vision
Polli, D., Altoè, P., Weingart, O., Spillane, K. M., Manzoni, C., Brida, D., Tomasello, G., Orlandi, G., Kukura, P., Mathies, R. A., et al. (2010) · Nature · doi:10.1038/nature09346 · Cited by 948
Self-citationCoherent ultrafast charge transfer in an organic photovoltaic blend
Falke, S. M., Rozzi, C. A., Brida, D., Maiuri, M., Amato, M., Sommer, E., De Sio, A., Rubio, A., Cerullo, G., Molinari, E., et al. (2014) · Science · doi:10.1126/science.1249771 · Cited by 554
Self-citationUltrafast Spectroscopy: State of the Art and Open Challenges
Maiuri, M., Garavelli, M., & Cerullo, G. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10533 · Cited by 460
Self-citationRichter, J. M., Branchi, F., Valduga de Almeida Camargo, F., Zhao, B., Friend, R. H., Cerullo, G., & Deschler, F. (2017) · Nature Communications · doi:10.1038/s41467-017-00546-z · Cited by 288
Self-citationAndrea Rozzi, C., Maria Falke, S., Spallanzani, N., Rubio, A., Molinari, E., Brida, D., Maiuri, M., Cerullo, G., Schramm, H., Christoffers, J., et al. (2013) · Nature Communications · doi:10.1038/ncomms2603 · Cited by 282
Self-citation
Metadata
- Authors
- Polli, D., Lüer, L., & Cerullo, G.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2007-10-01
- Volume
- 78
- Issue
- 10
- Pages
- 103108-103108
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1981919066
- Cited by
- 185
- References
- 0
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-time-resolution pump-probe system with broadband detection for the study of time-domain vibrational dynamics. https://app.cochat.ai/papers/10.1063/1.2800778
- The paper
- Polli, D., Lüer, L., & Cerullo, G. (2007). High-time-resolution pump-probe system with broadband detection for the study of time-domain vibrational dynamics. Review of Scientific Instruments. https://doi.org/10.1063/1.2800778
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.