The DOI matches its Crossref record.
KMC-1: A high resolution and high flux soft x-ray beamline at BESSY
Abstract
The crystal monochromator beamline KMC-1 at a BESSY II bending magnet covers the energy range from soft (1.7keV) to hard x-rays (12keV) employing the (n,−n) double crystal arrangement with constant beam offset. The monochromator is equipped with three sets of crystals, InSb, Si (111), and Si (422) which are exchangeable in situ within a few minutes. Beamline and monochromator have been optimized for high flux and high resolution. This could be achieved by (1) a windowless setup under ultrahigh-vacuum conditions up to the experiment, (2) by the use of only three optical elements to minimize reflection losses, (3) by collecting an unusually large horizontal radiation fan (6mrad) with the toroidal premirror, and (4) the optimization of the crystal optics to the soft x-ray range necessitating quasibackscattering crystal geometry (θBragg,max=82°) delivering crystal limited resolution. The multipurpose beamline is in use for a variety of user facilities such as extended x-ray absorption fine structure, ((Bio-)EXAFS) near-edge x-ray absorption fine structure (NEXAFS), absorption and fluorescence spectroscopy. Due to the windowless UHV setup the k edges of the technologically and biologically important elements such as Si, P, and S are accessible. In addition to these experiments this beamline is now extensively used for photoelectron spectroscopy at high kinetic energies. Photon flux in the 1011–1012photons∕s range and beamline resolving powers of more than E∕ΔE≈100.000 have been measured at selected energies employing Si (nnn) high order radiation in quasibackscattering geometry, thus photoelectron spectroscopy with a total instrumental resolution of about 150meV is possible. This article describes the design features of the beamline and reports some experimental results in the above mentioned fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Philippe, B., Park, B.-W., Lindblad, R., Oscarsson, J., Ahmadi, S., Johansson, E. M. J., & Rensmo, H. (2015) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b00348 · Cited by 462
Facilities for macromolecular crystallography at the Helmholtz-Zentrum Berlin
Mueller, U., Darowski, N., Fuchs, M. R., Förster, R., Hellmig, M., Paithankar, K. S., Pühringer, S., Steffien, M., Zocher, G., & Weiss, M. S. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512006395 · Cited by 396
Zhang, Y., Haitjema, J., Liu, X., Johansson, F., Lindblad, A., Castellanos, S., Ottosson, N., & Brouwer, A. M. (2017) · Journal of Micro/Nanopatterning Materials and Metrology · doi:10.1117/1.jmm.16.2.023510 · Cited by 67
Metadata
- Authors
- Schaefers, F., Mertin, M., & Gorgoi, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2007-12-01
- Volume
- 78
- Issue
- 12
- Pages
- 123102-123102
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2042612536
- Cited by
- 193
- References
- 0
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: KMC-1: A high resolution and high flux soft x-ray beamline at BESSY. https://app.cochat.ai/papers/10.1063/1.2808334
- The paper
- Schaefers, F., Mertin, M., & Gorgoi, M. (2007). KMC-1: A high resolution and high flux soft x-ray beamline at BESSY. Review of Scientific Instruments. https://doi.org/10.1063/1.2808334
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.