The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Facilities for macromolecular crystallography at the Helmholtz-Zentrum Berlin
Open accessAbstract
Three macromolecular crystallography (MX) beamlines at the Helmholtz-Zentrum Berlin (HZB) are available for the regional, national and international structural biology user community. The state-of-the-art synchrotron beamlines for MX BL14.1, BL14.2 and BL14.3 are located within the low-β section of the BESSY II electron storage ring. All beamlines are fed from a superconducting 7 T wavelength-shifter insertion device. BL14.1 and BL14.2 are energy tunable in the range 5-16 keV, while BL14.3 is a fixed-energy side station operated at 13.8 keV. All three beamlines are equipped with CCD detectors. BL14.1 and BL14.2 are in regular user operation providing about 200 beam days per year and about 600 user shifts to approximately 50 research groups across Europe. BL14.3 has initially been used as a test facility and was brought into regular user mode operation during the year 2010. BL14.1 has recently been upgraded with a microdiffractometer including a mini-κ goniometer and an automated sample changer. Additional user facilities include office space adjacent to the beamlines, a sample preparation laboratory, a biology laboratory (safety level 1) and high-end computing resources. In this article the instrumentation of the beamlines is described, and a summary of the experimental possibilities of the beamlines and the provided ancillary equipment for the user community is given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047337 · Cited by 16,463
iMOSFLM: a new graphical interface for diffraction-image processing with MOSFLM
Battye, T. G. G., Kontogiannis, L., Johnson, O., Powell, H. R., & Leslie, A. G. W. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910048675 · Cited by 2,860
Crystal structure of opsin in its G-protein-interacting conformation
Scheerer, P., Park, J. H., Hildebrand, P. W., Kim, Y. J., Krauß, N., Choe, H.-W., Hofmann, K. P., & Ernst, O. P. (2008) · Nature · doi:10.1038/nature07330 · Cited by 1,059
Crystal structure of the ligand-free G-protein-coupled receptor opsin
Park, J. H., Scheerer, P., Hofmann, K. P., Choe, H.-W., & Ernst, O. P. (2008) · Nature · doi:10.1038/nature07063 · Cited by 903
Crystal structure of metarhodopsin II
Choe, H.-W., Kim, Y. J., Park, J. H., Morizumi, T., Pai, E. F., Krauß, N., Hofmann, K. P., Scheerer, P., & Ernst, O. P. (2011) · Nature · doi:10.1038/nature09789 · Cited by 663
Gabadinho, J., Beteva, A., Guijarro, M., Rey-Bakaikoa, V., Spruce, D., Bowler, M. W., Brockhauser, S., Flot, D., Gordon, E. J., Hall, D. R., et al. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049510020005 · Cited by 229
BAMline: the first hard X-ray beamline at BESSY II
Görner, W., Hentschel, M., Müller, B. R., Riesemeier, H., Krumrey, M. K., Ulm, G., Diete, W., Klein, U., & Frahm, R. (2001) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(01)00466-1 · Cited by 207
KMC-1: A high resolution and high flux soft x-ray beamline at BESSY
Schaefers, F., Mertin, M., & Gorgoi, M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2808334 · Cited by 193
A Highly Porous Metal–Organic Framework with Open Nickel Sites
Gedrich, K., Senkovska, I., Klein, N., Stoeck, U., Henschel, A., Lohe, M. R., Baburin, I. A., Mueller, U., & Kaskel, S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201001735 · Cited by 167
Self-citationSchönfeld, D. L., Ravelli, R. B. G., Müeller, U., & Skerra, A. (2008) · Journal of Molecular Biology · doi:10.1016/j.jmb.2008.09.020 · Cited by 155
Cited by
Zhang, L., Lin, D., Sun, X., Curth, U., Drosten, C., Sauerhering, L., Becker, S., Rox, K., & Hilgenfeld, R. (2020) · Science · doi:10.1126/science.abb3405 · Cited by 2,895
Structure of the plastic-degrading Ideonella sakaiensis MHETase bound to a substrate
Palm, G. J., Reisky, L., Böttcher, D., Müller, H., Michels, E. A. P., Walczak, M. C., Berndt, L., Weiss, M. S., Bornscheuer, U. T., & Weber, G. (2019) · Nature Communications · doi:10.1038/s41467-019-09326-3 · Cited by 491
Self-citationXDSAPP: a graphical user interface for the convenient processing of diffraction data using XDS
Krug, M., Weiss, M. S., Heinemann, U., & Mueller, U. (2012) · Journal of Applied Crystallography · doi:10.1107/s0021889812011715 · Cited by 306
Self-citationMueller, U., Förster, R., Hellmig, M., Huschmann, F. U., Kastner, A., Malecki, P., Pühringer, S., Röwer, M., Sparta, K., Steffien, M., et al. (2015) · The European Physical Journal Plus · doi:10.1140/epjp/i2015-15141-2 · Cited by 299
Self-citationStructural basis for organohalide respiration
Bommer, M., Kunze, C., Fesseler, J., Schubert, T., Diekert, G., & Dobbek, H. (2014) · Science · doi:10.1126/science.1258118 · Cited by 268
Metadata
- Authors
- Mueller, U., Darowski, N., Fuchs, M. R., Förster, R., Hellmig, M., Paithankar, K. S., Pühringer, S., Steffien, M., Zocher, G., & Weiss, M. S.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2012-03-20
- Volume
- 19
- Issue
- 3
- Pages
- 442-449
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2121360634
- Cited by
- 396
- References
- 17
- FWCI
- 24.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Facilities for macromolecular crystallography at the Helmholtz-Zentrum Berlin. https://app.cochat.ai/papers/10.1107/s0909049512006395
- The paper
- Mueller, U., Darowski, N., Fuchs, M. R., Förster, R., Hellmig, M., Paithankar, K. S., Pühringer, S., Steffien, M., Zocher, G., & Weiss, M. S. (2012). Facilities for macromolecular crystallography at the Helmholtz-Zentrum Berlin. Journal of Synchrotron Radiation. https://doi.org/10.1107/s0909049512006395
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).