The DOI matches its Crossref record.
Gradiometric micro-SQUID susceptometer for scanning measurements of mesoscopic samples
Abstract
We have fabricated and characterized micro-SQUID susceptometers for use in low-temperature scanning probe microscopy systems. The design features the following: a 4.6μm diameter pickup loop; an integrated field coil to apply a local field to the sample; an additional counterwound pickup-loop/field-coil pair to cancel the background signal from the applied field in the absence of the sample; modulation coils to allow setting the SQUID at its optimum bias point (independent of the applied field), and shielding and symmetry that minimizes coupling of magnetic fields into the leads and body of the SQUID. We use a SQUID series array preamplifier to obtain a system bandwidth of 1MHz. The flux noise at 125mK is approximately 0.25μΦ0∕Hz above 10kHz, with a value of 2.5μΦ0∕Hz at 10Hz. The nominal sensitivity to electron spins located at the center of the pickup loop is approximately 200μB∕Hz above 10kHz, in the white-noise frequency region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A scanning superconducting quantum interference device with single electron spin sensitivity
Vasyukov, D., Anahory, Y., Embon, L., Halbertal, D., Cuppens, J., Neeman, L., Finkler, A., Segev, Y., Myasoedov, Y., Rappaport, M. L., et al. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.169 · Cited by 421
Self-citationSubpicotesla Diamond Magnetometry
Wolf, T., Neumann, P., Nakamura, K., Sumiya, H., Ohshima, T., Isoya, J., & Wrachtrup, J. (2015) · Physical Review X · doi:10.1103/physrevx.5.041001 · Cited by 378
Persistent Currents in Normal Metal Rings
Bleszynski-Jayich, A. C., Shanks, W. E., Peaudecerf, B., Ginossar, E., von Oppen, F., Glazman, L., & Harris, J. G. E. (2009) · Science · doi:10.1126/science.1178139 · Cited by 337
Imaging currents in HgTe quantum wells in the quantum spin Hall regime
Nowack, K. C., Spanton, E. M., Baenninger, M., König, M., Kirtley, J. R., Kalisky, B., Ames, C., Leubner, P., Brüne, C., Buhmann, H., et al. (2013) · Nature Materials · doi:10.1038/nmat3682 · Cited by 265
Self-citationVariational-state quantum metrology
Koczor, B., Endo, S., Jones, T., Matsuzaki, Y., & Benjamin, S. C. (2020) · New Journal of Physics · doi:10.1088/1367-2630/ab965e · Cited by 101
Metadata
- Authors
- Huber, M. E., Koshnick, N. C., Bluhm, H., Archuleta, L. J., Azua, T., Björnsson, P. G., Gardner, B. W., Halloran, S. T., Lucero, E. A., & Moler, K. A.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2008-05-01
- Volume
- 79
- Issue
- 5
- Pages
- 053704-053704
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2046536691
- Cited by
- 171
- References
- 0
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gradiometric micro-SQUID susceptometer for scanning measurements of mesoscopic samples. https://app.cochat.ai/papers/10.1063/1.2932341
- The paper
- Huber, M. E., Koshnick, N. C., Bluhm, H., Archuleta, L. J., Azua, T., Björnsson, P. G., Gardner, B. W., Halloran, S. T., Lucero, E. A., & Moler, K. A. (2008). Gradiometric micro-SQUID susceptometer for scanning measurements of mesoscopic samples. Review of Scientific Instruments. https://doi.org/10.1063/1.2932341
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).