CoChat

SQUID instruments and shielding for low-level magnetic measurements

Zimmerman, James E. · 1977 · Journal of Applied Physics
Cited by 132

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We have used a thick-walled aluminum enclosure to provide low-frequency shielding for biomagnetic studies with SQUID magnetic gradiometers. The shield provides an attenuation proportional to frequency above 1/3 Hz. A 24-hole fractional-turn SQUID gradiometer has been used in the enclosure to carry out studies of magnetoencephalography on humans. An ’’asymmetric’’ configuration for a second-derivative gradiometer has been developed which provides a significant increase in sensitivity and resolution over more conventional symmetric arrays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.323659

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 132

Metadata

Authors
Zimmerman, J. E.
Venue
Journal of Applied Physics
Published
1977-02-01
Volume
48
Issue
2
Pages
702-710
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2085879401
Cited by
132
References
2
FWCI
4.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SQUID instruments and shielding for low-level magnetic measurements. https://app.cochat.ai/papers/10.1063/1.323659
The paper
Zimmerman, J. E. (1977). SQUID instruments and shielding for low-level magnetic measurements. Journal of Applied Physics. https://doi.org/10.1063/1.323659

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.