The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Fabrication of microfluidic devices using polydimethylsiloxane
Open accessAbstract
Polydimethylsiloxane (PDMS) is nearly ubiquitous in microfluidic devices, being easy to work with, economical, and transparent. A detailed protocol is provided here for using PDMS in the fabrication of microfluidic devices to aid those interested in using the material in their work, with information on the many potential ways the material may be used for novel devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825780 · Cited by 1,098
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Aligned Carbon Nanotube−Polymer Hybrid Architectures for Diverse Flexible Electronic Applications
Jung, Y. J., Kar, S., Talapatra, S., Soldano, C., Viswanathan, G., Li, X., Yao, Z., Ou, F. S., Avadhanula, A., Vajtai, R., et al. (2006) · Nano Letters · doi:10.1021/nl052238x · Cited by 316
The microfluidic palette: A diffusive gradient generator with spatio-temporal control
Atencia, J., Morrow, J. B., & Locascio, L. E. (2009) · Lab on a Chip · doi:10.1039/b902113b · Cited by 156
Replication and Compression of Surface Structures with Polydimethylsiloxane Elastomer
Lisensky, G. C., Campbell, D. J., Beckman, K. J., et al. (1999) · Journal of Chemical Education · doi:10.1021/ed076p537 · Cited by 118
Microfluidics as a functional tool for cell mechanics
Vanapalli, S. A., Duits, M. H. G., & Mugele, F. G. (2009) · Biomicrofluidics · doi:10.1063/1.3067820 · Cited by 111
Polydimethylsiloxane microfluidic chip with integrated microheater and thermal sensor
Wu, J., Cao, W., Wen, W., et al. (2009) · Biomicrofluidics · doi:10.1063/1.3058587 · Cited by 100
Lewpiriyawong, N., Yang, C., & Lam, Y. C. (2008) · Biomicrofluidics · doi:10.1063/1.2973661 · Cited by 95
Gong, X., & Wen, W. (2009) · Biomicrofluidics · doi:10.1063/1.3098963 · Cited by 61
Hybrid macro–micro fluidics system for a chip-based biosensor
Tamanaha, C. R., Whitman, L. J., & Colton, R. J. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/2/401 · Cited by 59
Microfluidic electrospinning of biphasic nanofibers with Janus morphology
Srivastava, Y., Márquez, M., & Thorsen, T. (2009) · Biomicrofluidics · doi:10.1063/1.3009288 · Cited by 56
Das, S. K., Chung, S., Zervantonakis, I. K., Atnafu, J., & Kamm, R. D. (2008) · Biomicrofluidics · doi:10.1063/1.2988313 · Cited by 32
A rigid poly(dimethylsiloxane) sandwich electrophoresis microchip based on thin‐casting method
Liu, C., Cui, D., Cai, H., et al. (2006) · Electrophoresis · doi:10.1002/elps.200500581 · Cited by 23
Cited by
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I. D., McCluskey, D. K., Tan, C. K. L., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,495
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964
Self-citationDesign of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Self-citation
Metadata
- Authors
- Friend, J., & Yeo, L.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2010-03-15
- Volume
- 4
- Issue
- 2
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2078224390
- Cited by
- 425
- References
- 15
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.