CoChat

The quality factor of a superconducting rf resonator in a magnetic field

Ulmer, S., Kracke, H., Blaum, K., Kreim, S., Mooser, A., Quint, W., Rodegheri, C. C., Walz, J. · 2009 · Review of Scientific Instruments

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

The quality factor of a superconducting NbTi resonator at 1.6 MHz in a magnetic field up to 1.2 T as well as its temperature dependence is investigated. A hysteresis effect in the superconducting surface resistance as a function of the magnetic field is observed. An unloaded Q-value of the resonator of 40 500 is achieved at 3.9 K. It is shown that this Q-value is limited by dielectric losses in the FORMVAR insulation of the coils wire. The details of the Q-value optimization are discussed. In the temperature dependence of the Q-value a steep decrease is observed above T≈7.5 K. Finally, the implications of these measurements for real trap experiments are discussed in detail.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.3271537

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists are queued

They are fetched later and appear here then.

References 37 · Cited by 56

Research works printed but not linked: 3

  1. E. Wingfield, M.S. thesis, Florida State University, 2007.
  2. R. Nguyen, Thesis, Florida State University, 1998.
  3. 2004, Introduction to Superconductivity

Metadata

Authors
Ulmer, S., Kracke, H., Blaum, K., Kreim, S., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J.
Affiliations
  • GSI Helmholtz Centre for Heavy Ion Research (DE)
  • Johannes Gutenberg University Mainz (DE)
  • Heidelberg University (DE)
Venue
Review of Scientific Instruments
Published
2009-12-01
Volume
80
Issue
12
Pages
123302-123302
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2046720729
Cited by
56
References
37
Citations by year
2026: 2 · 2025: 3 · 2024: 7 · 2023: 3 · 2022: 9 · 2021: 1 · 2020: 4 · 2019: 1 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 3 · 2014: 2 · 2013: 2 · 2012: 4
FWCI
7.12
Type
journal article
Language
en
Open access
closed
Locations
  • Review of Scientific Instruments (publishedVersion)
  • PubMed (publishedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • Max Planck Digital Library (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
Funders
  • International Max Planck Research School for Environmental, Cellular and Molecular Microbiology
  • European Commission
Topics
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Particle Accelerators and Free-Electron Lasers
Keywords
quality factor, NBTI, magnetic field dependence, dielectric loss, temperature dependence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The quality factor of a superconducting rf resonator in a magnetic field. https://app.cochat.ai/papers/10.1063/1.3271537
The paper
Ulmer, S., Kracke, H., Blaum, K., Kreim, S., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J. (2009). The quality factor of a superconducting rf resonator in a magnetic field. Review of Scientific Instruments. https://doi.org/10.1063/1.3271537

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.