Off-resonance electronic detection and cooling of ions in a Penning trap

Open access
Ringleb, Stefan, Kiffer, Markus, Vogel, Manuel, Stöhlker, Thomas · 2024 · The European Physical Journal Plus

Abstract

We present a non-destructive electronic detector for stored charged particles in a Penning trap that uses a symmetric electrode arrangement for signal pickup and a resonator without tap. This system has advantageous off-resonance features which are demonstrated by means of detection and cooling measurements with highly charged ions in a cryogenic Penning trap. In particular, it allows for particle detection across a wide range of frequencies that is not concomitant with cooling and offers a novel way to tune a trap with the help of non-destructive measurements on large particle ensembles.

Overview

CoChat Summary

TL;DR

The paper presents a symmetric dual-electrode resonant circuit for non-destructive detection and cooling of highly charged ions in a cryogenic Penning trap, enabling off-resonance detection without concomitant cooling. It uses this to measure off-resonance cooling rates and axial de-phasing, and to tune the trap with large ion ensembles.

Key findings

  • The dual-electrode resonator allows axial-frequency detection far outside its bandwidth: the resonator covers less than 200 kHz (1270–1450 kHz), while measured axial frequencies of stored Ne⁸⁺ ions range from 750 to 1700 kHz.
  • Off-resonance detection can be nearly cooling-free: at a trap potential of U₀ = 300 V, the real part of the resonator impedance is less than 2% of the on-resonance value Rₚ, so centre-of-mass cooling is negligible and the axial de-phasing rate γₐₓ can be separated out.
  • A cooling-rate scan over U₀ = 127.5–185.5 V, corresponding to f_z = 1.23–1.50 MHz, is fitted with the frequency-dependent impedance; the fit yields a resonance frequency f₀ = 1.37 MHz and quality factor Q = 8.5.
  • Off-resonance signal decay versus correction-electrode voltages identifies the lowest axial de-phasing and hence highest trap harmonicity; the design-expected optimum voltage pair of 17.7 V and 130.2 V for inner and outer correction electrodes lies fairly outside the marked optimal region.
  • For ion numbers N between 20,000 and 40,000, higher N shows an earlier increase in signal-decay rate, attributed to stronger ion–ion interaction and a broader axial-frequency distribution from space charge.

Methods

  • Experiments used the cryogenic Penning trap of the HILITE experiment; bunches of helium-like Ne⁸⁺ ions were produced externally and dynamically captured, then detected and cooled non-destructively via a resonant LC circuit. The trap endcaps have a separation of 22.4 mm, an inner diameter of 15 mm, and a 4 mm central hole.
  • The dual-electrode resonator is a normal-conducting circuit of high-purity copper wire wound around a toroidal PTFE core, connected to the two inner correction electrodes; the effective electrode distance is D = 33 mm, and the signal is amplified by a model CX-4 Stahl Electronics low-noise cryogenic amplifier.
  • Measurements used a Keysight CXA 9000B spectrum analyser in span mode for axial-frequency distributions and in zero-span mode with a 1 kHz window for time-dependent ion signals; cooling rates were obtained by fitting Eq. (2) to the decay, and the cooling scan was fitted using Eq. (4) with the frequency-dependent impedance of Eq. (6).

Limitations

  • Stated: the measurable frequency window is presently limited by the available trap voltages U₀, although a larger range would be possible.
  • Stated: Q = 8.5 is comparatively small; the setup is dedicated to large numbers of highly charged ions moving in phase, and it is unclear whether the overall ion–circuit interaction would be predictable otherwise, since conventional resistive cooling requires γ ≪ ω_z.
  • Stated: the expected optimum tuning voltages lie outside the measured optimal region, attributed to manufacturing errors and space charge of the ion cloud, which can hardly be predicted without deep knowledge of the ion-cloud parameters.
  • Evident from the text: the energy-flow model omits radial motions because they contributed only marginally for the present on-axis injection, so the de-phasing analysis is scoped to axial centre-of-mass and relative axial motions.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1140/epjp/s13360-024-05183-2

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

2 Valid · 0 Not valid · 3 Not checked · 19 Own results and interpretations

9 more claims

Create a free account to see all 24 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 9
  • Probably not a substantial claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 20 references

Research works printed but not linked: 3

  1. H.G. Dehmelt, Bull. Am. Phys. Soc. 7, 470 (1962)
  2. H.G. Dehmelt, Bull. Am. Phys. Soc. 8, 23 (1963)
  3. H. Paul, W. Hill, The Art of Electronics, 3rd edn. (Cambridge University Press, Cambridge, 2015)

Cited by

See all 3

Metadata

Authors
Ringleb, S., Kiffer, M., Vogel, M., & Stöhlker, T.
Affiliations
  • Friedrich Schiller University Jena (DE)
  • GSI Helmholtz Centre for Heavy Ion Research (DE)
Corresponding author
Ringleb, Stefan
Venue
The European Physical Journal Plus
Published
2024-05-10
Volume
139
Issue
5
ISSN
2190-5444 (ISSN-L)
OpenAlex
W4396808731
Cited by
3
References
20
Citations by year
2025: 1 · 2024: 2
FWCI
0.52
Type
journal article
Language
en
Open access
Licence
Locations
  • The European Physical Journal Plus (publishedVersion, cc-by)
  • GSI Repository (German Federal Government) (submittedVersion, cc-by)
  • GSI Repository (German Federal Government)
Funders
Friedrich-Schiller-Universität Jena
Topics
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Dust and Plasma Wave Phenomena
Keywords
Penning trap, ion cooling, highly charged ions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Off-resonance electronic detection and cooling of ions in a Penning trap. https://app.cochat.ai/papers/10.1140/epjp/s13360-024-05183-2
The paper
Ringleb, S., Kiffer, M., Vogel, M., & Stöhlker, T. (2024). Off-resonance electronic detection and cooling of ions in a Penning trap. The European Physical Journal Plus. https://doi.org/10.1140/epjp/s13360-024-05183-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.