Magnetic field fluctuations arising from thermal motion of electric charge in conductors
The DOI matches its Crossref record.
Abstract
A model is developed for the source of magnetic field fluctuations emanating from thermal agitation of electric charge in conductors. The calculation of the thermal magnetic noise with the model involves the solution of a general volume conductor forward problem. Frequency-dependent equations for this problem are derived from Maxwell’s equations. The model is applied to calculate the magnetic noise generated by infinite conducting slabs. A good agreement between theoretical predictions and experimental results were found. Thermal magnetic noise fields inside magnetically shielded rooms are estimated and noise in biomagnetic measurements is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Microscopic Atom Optics: From Wires to an Atom Chip
Folman, R., Krüger, P., Schmiedmayer, J., Denschlag, J., & Henkel, C. (2002) · Advances In Atomic, Molecular, and Optical Physics · doi:10.1016/s1049-250x(02)80011-8 · Cited by 658
The Casimir force: background, experiments, and applications
Lamoreaux, S. K. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/1/r04 · Cited by 592
Magnetic microtraps for ultracold atoms
Fortágh, J., & Zimmermann, C. (2007) · Reviews of Modern Physics · doi:10.1103/revmodphys.79.235 · Cited by 579
Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields
Savukov, I. M., Seltzer, S. J., Romalis, M. V., & Sauer, K. L. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.063004 · Cited by 313
Resonantly Detecting Axion-Mediated Forces with Nuclear Magnetic Resonance
Arvanitaki, A., & Geraci, A. A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.161801 · Cited by 248
A low-power, high-sensitivity micromachined optical magnetometer
Mhaskar, R., Knappe, S., & Kitching, J. (2012) · Applied Physics Letters · doi:10.1063/1.4770361 · Cited by 171
The brain timewise: how timing shapes and supports brain function
Hari, R., & Parkkonen, L. (2015) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2014.0170 · Cited by 98
“The fundamental limit is set by the noise due to the thermal motion of charged particles in the body, which is estimated to be about 0.2 fT/ p Hz [46].”
BackgroundInfluential
Metadata
- Authors
- Varpula, T., & Poutanen, T.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1984-06-01
- Volume
- 55
- Issue
- 11
- Pages
- 4015-4021
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1969049512
- Cited by
- 136
- References
- 0
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.