The DOI matches its Crossref record.
The Maia Spectroscopy Detector System: Engineering for Integrated Pulse Capture, Low-Latency Scanning and Real-Time Processing
Abstract
The Maia detector system is engineered for energy dispersive x‐ray fluorescence spectroscopy and elemental imaging at photon rates exceeding 107/s, integrated scanning of samples for pixel transit times as small as 50μs and high definition images of 108 pixels and real‐time processing of detected events for spectral deconvolution and online display of pure elemental images. The system developed by CSIRO and BNL combines a planar silicon 384 detector array, application‐specific integrated circuits for pulse shaping and peak detection and sampling and optical data transmission to an FPGA‐based pipelined, parallel processor. This paper describes the system and the underpinning engineering solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Johnson, A. A. T., Kyriacou, B., Callahan, D. L., Carruthers, L., Stangoulis, J., Lombi, E., & Tester, M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024476 · Cited by 411
Elemental and Chemically Specific X-ray Fluorescence Imaging of Biological Systems
Pushie, M. J., Pickering, I. J., Korbas, M., Hackett, M. J., & George, G. N. (2014) · Chemical Reviews · doi:10.1021/cr4007297 · Cited by 332
Gräfe, M., Donner, E., Collins, R. N., & Lombi, E. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.02.044 · Cited by 186
Zhang, J. Z., Bryce, N. S., Siegele, R., Carter, E. A., Paterson, D., de Jonge, M. D., Howard, D. L., Ryan, C. G., & Hambley, T. W. (2012) · Integrative Biology · doi:10.1039/c2ib20121f · Cited by 37
Self-citationMethods for Visualizing Elemental Distribution in Hyperaccumulator Plants
van der Ent, A., Purwadi, I., Harris, H. H., Kopittke, P. M., Przybyłowicz, W. J., & Mesjasz-Przybyłowicz, J. (2021) · Mineral Resource Reviews · doi:10.1007/978-3-030-58904-2_10 · Cited by 5
Metadata
- Authors
- Kirkham, R., Dunn, P. A., Kuczewski, A. J., Siddons, D. P., Dodanwela, R., Moorhead, G. F., Ryan, C. G., De Geronimo, G., Beuttenmuller, R., Pinelli, D., Pfeffer, M., Davey, P., Jensen, M., Paterson, D. J., de Jonge, M. D., Howard, D. L., Küsel, M., McKinlay, J., Garrett, R., Gentle, I., Nugent, K., & Wilkins, S.
- Venue
- AIP Conference Proceedings
- Publisher
- AIP
- Published
- 2010
- Pages
- 240-243
- ISSN
- 0094-243X (ISSN-L)
- OpenAlex
- W2084983527
- Cited by
- 185
- References
- 0
- FWCI
- 48.89
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Maia Spectroscopy Detector System: Engineering for Integrated Pulse Capture, Low-Latency Scanning and Real-Time Processing. https://app.cochat.ai/papers/10.1063/1.3463181
- The paper
- Kirkham, R., Dunn, P. A., Kuczewski, A. J., Siddons, D. P., Dodanwela, R., Moorhead, G. F., Ryan, C. G., De Geronimo, G., Beuttenmuller, R., Pinelli, D., Pfeffer, M., Davey, P., Jensen, M., Paterson, D. J., de Jonge, M. D., Howard, D. L., Küsel, M., McKinlay, J., Garrett, R., . . . Wilkins, S. (2010). The Maia Spectroscopy Detector System: Engineering for Integrated Pulse Capture, Low-Latency Scanning and Real-Time Processing. AIP Conference Proceedings. https://doi.org/10.1063/1.3463181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.