Magnetocardiography with sensors based on giant magnetoresistance
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Biomagnetic signals, mostly due to the electrical activity in the body, are very weak and they can only be detected by the most sensitive magnetometers, such as Superconducting Quantum Interference Devices (SQUIDs). We report here biomagnetic recordings with hybrid sensors based on Giant MagnetoResistance (GMR). We recorded magnetic signatures of the electric activity of the human heart (magnetocardiography) in healthy volunteers. The P-wave and QRS complex, known from the corresponding electric recordings, are clearly visible in the recordings after an averaging time of about 1 min. Multiple recordings at different locations over the chest yielded a dipolar magnetic field map and allowed localizing the underlying current sources. The sensitivity of the GMR-based sensors is now approaching that of SQUIDs and paves way for spin electronics devices for functional imaging of the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Cited by
Magnetic sensors-A review and recent technologies
Khan, M. A., Sun, J., Li, B., Przybysz, A., & Kosel, J. (2021) · Engineering Research Express · doi:10.1088/2631-8695/ac0838 · Cited by 315
Magnetoencephalography: From SQUIDs to neuroscience
Hari, R., & Salmelin, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.074 · Cited by 285
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques
Elfouly, T., & Alouani, A. (2024) · Sensors · doi:10.3390/s24186017 · Cited by 19
“In [64], the authors used hybrid sensors based on Giant Mag-netoresistance (GMR) to capture the magnetic signatures of the heart’s electrical activity (magnetocardiography) in healthy volunteers.”
MethodMa, J., Yang, Z., & Uchiyama, T. (2019) · AIP Advances · doi:10.1063/1.5129842 · Cited by 7
Metadata
- Authors
- Pannetier-Lecoeur, M., Parkkonen, L., Sergeeva-Chollet, N., Polovy, H., Fermon, C., & Fowley, C.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2011-04-11
- Volume
- 98
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2049934815
- Cited by
- 113
- References
- 2
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.