Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques
Open accessThe DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
Heart diseases remain one of the leading causes of morbidity and mortality worldwide, necessitating innovative diagnostic methods for early detection and intervention. An electrocardiogram (ECG) is a well-known technique for the preliminary diagnosis of heart conditions. However, it can not be used for continuous monitoring due to skin irritation. It is well known that every body organ generates a magnetic field, and the heart generates peak amplitudes of about 10 to 100 pT (measured at a distance of about 3 cm above the chest). This poses challenges to capturing such signals. This paper reviews the different techniques used to capture the heart’s magnetic signals along with their limitations. In addition, this paper provides a comprehensive review of the different approaches that use the heart-generated magnetic field to diagnose several heart diseases. This research reveals two aspects. First, as a noninvasive tool, the use of the heart’s magnetic field signal can lead to more sensitive advanced heart disease diagnosis tools, especially when continuous monitoring is possible and affordable. Second, its current use is limited due to the lack of accurate, affordable, and portable sensing technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 The magnetic fields of different body organs and the devices capable of sensing them [69].](https://figures.cochat.ai/paper-figures/29b20fc88cdd43b8b41061ad6e77b5f8/harnessing-the-hearts-magnetic-field-for-advanced-diagnostic-techniques-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Its EMF is generated throughout the cardiac cycle and is mainly attributed to transmembrane Na+, K+, and Ca2+ fluxes during depolarization and repolarization, generating time-varying magnetic signals, detectable by sensitive biosensors, in line with Maxwell’s equations [Figure 1] [22,23,24,25,26].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Field strength is ~1 nT near the myocardium, ~0.1 nT at the body surface, and 10–100 pT a few centimeters above the chest—much weaker than the Earth’s field but far stronger than cortical sources [Figure 1] [20,21,22,23,25,26,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Due to their femtotesla sensitivity and vector-field reconstruction capability, SQUIDs remain essential tools for validating the foundations of the heart’s electromagnetic structure and coherence [20,21,23,25,26].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both SQUIDs and OPMs are highly sensitive to ambient magnetic interference, thus requiring magnetically shielded rooms or advanced active noise-cancelation systems to achieve sufficient signal-to-noise ratios for reliable isolation of cardiac magnetic signals, limitations that hinder widespread clinical scalability [23,24,25,26,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“OPMs on the other hand, like the QZFM series by QuSpin (QuSpin Inc., Louisville, CO, USA), represent a promising, emerging technology that combines near-SQUID sensitivity with room-temperature operation while offering scalability towards wearable and multi-subject recording [25,26,44,45].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measured
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916 · cited 1×
“• Principle: They are highly sensitive devices used to measure magnetic fields [53].”
BackgroundModern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review
Hussain, S., Mubeen, I., Ullah, N., Shah, S. S. U. D., Khan, B. A., Zahoor, M., Ullah, R., Khan, F. A., & Sultan, M. A. (2022) · BioMed Research International · doi:10.1155/2022/5164970 · Cited by 787 · cited 1×
“In [32], the authors presented a review of the modern diagnostic based on imaging techniques and their risks.”
BackgroundMagnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Pinto-Coelho, L. (2023) · Bioengineering · doi:10.3390/bioengineering10121435 · Cited by 676
AI in diagnostic imaging: Revolutionising accuracy and efficiency
Khalifa, M., & Albadawy, M. (2024) · Computer Methods and Programs in Biomedicine Update · doi:10.1016/j.cmpbup.2024.100146 · Cited by 517
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392 · cited 1×
“The seminal work by Baule and McFee (1963) [39] on the detection of magnetic fields produced by the heart and the brain set the stage for the development of magnetocardiography (MCG) [40].”
BackgroundSQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Magnetoelectrics for magnetic sensor applications: status, challenges and perspectives
Wang, Y., Li, J., & Viehland, D. (2014) · Materials Today · doi:10.1016/j.mattod.2014.05.004 · Cited by 358 · cited 1×
“…applied to ME composites, an electric charge across the piezoelectric phase is induced due to the piezoelectricity that results from the deformation produced by the ferromagnetic component due to the magnetostriction that is transferred to the ferroelectric component via interfacial bonding [74].”
BackgroundArtificial intelligence in clinical medicine: catalyzing a sustainable global healthcare paradigm
Krishnan, G., Singh, S., Pathania, M., Gosavi, S., Abhishek, S., Parchani, A., & Dhar, M. (2023) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2023.1227091 · Cited by 296
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277 · cited 4×
“• Principle: They use the saturation of a ferromagnetic core in an alternating magnetic field to detect changes in the external magnetic field [45–47] and even down to 100 fT/ √ Hz [38,47,48].”
BackgroundMethodInfluential
Research works printed but not linked: 2
- Mubarik, I.A. (2024, July 25). Holter Monitor, Available online: https://www.ncbi.nlm.nih.gov/books/NBK538203/.
- Plonsey, R. (2007). Bioelectricity: A Quantitative Approach, Springer.
Cited by
Hybrid sensor integration in wearable devices for improved cardiovascular health monitoring
Khan, B., Khan, W., Masrur, M. A., Khalid, R. T., Awais, M., Khan, B., Khoo, B. L., & Abdullah, S. (2025) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2025.100889 · Cited by 36
Tian, K., Zhang, X., Yang, J., Hu, Y., Zhang, A., Xiang, M., Zheng, S., & Liu, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3562994 · Cited by 15
Dejneka, Z., Homa, D., Theis, L., Wang, A., & Pickrell, G. (2025) · Sensors · doi:10.3390/s25030841 · Cited by 9
Flow Rate Estimation Based on Magnetic Particle Detection Using a Miniatured High-Sensitivity OPM
Liu, Y., Huang, B., Li, J., Li, R., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3565069 · Cited by 15
“Every time the heart beats, electrical current flows through the myocardium of the heart [42], producing a magnetic field that is close in amplitude to MPs.”
Yaga, L., Amemiya, M., Natsume, Y., Shibuya, T., & Sasano, T. (2025) · Sensors · doi:10.3390/s25154642 · Cited by 9
“Several studies utilizing induction coils, fluxgate sensors, and scalar OPMs have reported that they do not require magnetic shielding or cooling systems [4,32–34].”
Metadata
- Authors
- Elfouly, T., & Alouani, A.
- Affiliations
- Tennessee Technological University (US)
- Corresponding author
- Elfouly, Tarek
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2024-09-18
- Volume
- 24
- Issue
- 18
- Pages
- 6017
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC11435997
- OpenAlex
- W4402601201
- Semantic Scholar
- ed6fdfc640046866e147f9d8e02716156c043978
- Cited by
- 19
- References
- 82
- Citations by year
- 2026: 10 · 2025: 9
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- cardiac magnetic field, magnetocardiography, heart disease diagnosis, non-invasive cardiac monitoring, continuous cardiac monitoring, electrocardiogram limitations
- MeSH terms
- Electrocardiography, Heart, Heart Diseases, Humans, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques. https://app.cochat.ai/papers/10.3390/s24186017
- The paper
- Elfouly, T., & Alouani, A. (2024). Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques. Sensors. https://doi.org/10.3390/s24186017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.