Cited by 235

The DOI matches its Crossref record.

Note: Integration of trapped ion mobility spectrometry with mass spectrometry

Open access
Fernandez-Lima, F. A., Kaplan, D. A., Park, M. A.·2011·Review of Scientific Instruments

Abstract

The integration of a trapped ion mobility spectrometer (TIMS) with a mass spectrometer (MS) for complementary fast, gas-phase mobility separation prior to mass analysis (TIMS-MS) is described. The ion transmission and mobility separation are discussed as a function of the ion source condition, bath gas velocity, analysis scan speed, RF ion confinement, and downstream ion optical conditions. TIMS mobility resolution depends on the analysis scan speed and the bath gas velocity, with the unique advantage that the IMS separation can be easily tuned from high speed (∼25 ms) for rapid analysis to slower scans for higher mobility resolution (R > 80).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.3665933

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 235

Metadata

Authors
Fernandez-Lima, F. A., Kaplan, D. A., & Park, M. A.
Venue
Review of Scientific Instruments
Published
2011-12-01
Volume
82
Issue
12
Pages
126106-126106
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2008847634
Cited by
235
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Note: Integration of trapped ion mobility spectrometry with mass spectrometry. https://app.cochat.ai/papers/10.1063/1.3665933
The paper
Fernandez-Lima, F. A., Kaplan, D. A., & Park, M. A. (2011). Note: Integration of trapped ion mobility spectrometry with mass spectrometry. Review of Scientific Instruments. https://doi.org/10.1063/1.3665933

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.