The DOI matches its Crossref record.
Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis
Abstract
We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge (∼285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Efficient organic solar cells processed from hydrocarbon solvents
Zhao, J., Li, Y., Yang, G., Jiang, K., Lin, H., Ade, H., Ma, W., & Yan, H. (2016) · Nature Energy · doi:10.1038/nenergy.2015.27 · Cited by 2,367
Self-citationLi, S., Ye, L., Zhao, W., Zhang, S., Mukherjee, S., Ade, H., & Hou, J. (2016) · Advanced Materials · doi:10.1002/adma.201602776 · Cited by 1,380
Self-citationA Large‐Bandgap Conjugated Polymer for Versatile Photovoltaic Applications with High Performance
Zhang, M., Guo, X., Ma, W., Ade, H., & Hou, J. (2015) · Advanced Materials · doi:10.1002/adma.201502110 · Cited by 1,247
Self-citationStructural control of mixed ionic and electronic transport in conducting polymers
Rivnay, J., Inal, S., Collins, B. A., Sessolo, M., Stavrinidou, E., Strakosas, X., Tassone, C., Delongchamp, D. M., & Malliaras, G. G. (2016) · Nature Communications · doi:10.1038/ncomms11287 · Cited by 939
Self-citationSingle‐Junction Binary‐Blend Nonfullerene Polymer Solar Cells with 12.1% Efficiency
Zhao, F., Dai, S., Wu, Y., Zhang, Q., Wang, J., Jiang, L., Ling, Q., Wei, Z., Ma, W., You, W., et al. (2017) · Advanced Materials · doi:10.1002/adma.201700144 · Cited by 699
Self-citation
Metadata
- Authors
- Gann, E., Young, A. T., Collins, B. A., Yan, H., Nasiatka, J., Padmore, H. A., Ade, H., Hexemer, A., & Wang, C.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2012-04-01
- Volume
- 83
- Issue
- 4
- Pages
- 045110-045110
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2063913793
- Cited by
- 443
- References
- 0
- FWCI
- 27.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis. https://app.cochat.ai/papers/10.1063/1.3701831
- The paper
- Gann, E., Young, A. T., Collins, B. A., Yan, H., Nasiatka, J., Padmore, H. A., Ade, H., Hexemer, A., & Wang, C. (2012). Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis. Review of Scientific Instruments. https://doi.org/10.1063/1.3701831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.