The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Signal modeling for ion cyclotron resonance
Abstract
A new signal model, called the rotating electric monopole signal model, is developed for ion cyclotron resonance (ICR) experiments. Unlike prior signal models, the model is applicable to all forms of ICR spectroscopy which use radio-frequency detection methods. The signal model consists of a rotating electric monopole which is shown to be equivalent for signal generation purposes to a rotating electric dipole and for a macroscopic number of ions to a rotating electric polarization. The rotating polarization induces an alternating charge in the plates of the ICR cell and an alternating current between and an alternating voltage across the plates of the ICR cell. A noise analysis is performed, and if amplifier noise is neglected, the ICR sensitivity according to the model is found to be inversely proportional to the ion mass. This is the same sensitivity dependence as is found with conventional ICR power absorption experiments. The ICR voltage signal strength is inversely proportional to ion mass if the monitoring circuit is predominantly resistive and is independent of ion mass if the circuit is predominantly capacitive. The model clearly illustrates the parallelism between signal generation in ICR spectroscopy and signal generation in other coherent radiation spectroscopies such as NMR and microwave spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Currents to Conductors Induced by a Moving Point Charge
Shockley, W. (1938) · Journal of Applied Physics · doi:10.1063/1.1710367 · Cited by 1,300
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
The effects of fear and anger facial expressions on approach- and avoidance-related behaviors
Marsh, A. A., Ambady, N., & Kleck, R. E. (2005) · Emotion · doi:10.1037/1528-3542.5.1.119 · Cited by 588
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Bollen, G., Moore, R. B., Savard, G., & Stolzenberg, H. (1990) · Journal of Applied Physics · doi:10.1063/1.346185 · Cited by 312
Metadata
- Authors
- Comisarow, M. B.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1978-11-01
- Volume
- 69
- Issue
- 9
- Pages
- 4097-4104
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2043314046
- Cited by
- 194
- References
- 2
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Signal modeling for ion cyclotron resonance. https://app.cochat.ai/papers/10.1063/1.437143
- The paper
- Comisarow, M. B. (1978). Signal modeling for ion cyclotron resonance. The Journal of Chemical Physics. https://doi.org/10.1063/1.437143
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.