The DOI matches its Crossref record.
Relaxation and spectral line shape in Fourier transform ion resonance spectroscopy
Abstract
Analytical expressions for Fourier transform ion cyclotron resonance (FT-ICR) line shape [absorption mode, dispersion mode, and magnitude (absolute value) mode] are derived for coherently excited ions that undergo both reactive and nonreactive ion–molecule collisions. The expressions are valid at arbitrary sample pressure, and reduce to particularly simple form in the ’’zero-pressure’’ limit (essentially no ion–molecule collisions during the data acquisition period) or ’’high-pressure’’ limit (many ion–molecule collisions during the data acquisition period). The zero-pressure line shape has been analyzed in earlier papers; in this paper, various useful properties of the high-pressure line shape (e.g., linewidth, mass resolution, and upper mass limit) are tabulated for various choices of the fraction of maximal absorption (or magnitude) peak height at which linewidth is to be measured. Absorption, dispersion, and magnitude spectra are plotted for zero-pressure and high-pressure limits, and also for an intermediate pressure. Convenient reference graphs of high-pressure FT-ICR linewidth, mass resolution, and upper mass limit as functions of ionic mass and time-domain ICR half-life for singly charged ions at magnetic field strength of 2 T are included. Finally, the intermediate-pressure resolution is calculated as a function of acquisition period at fixed pressure, to shown that near-optimal mass resolution (to within 90% of maximal absorption-mode resolution, or 95% of maximal magnitude-mode resolution) is achieved by truncating the FT-ICR time-domain signal after just three relaxation times. The particularly simple trade-off between signal-to-noise ratio and mass resolution in FT-ICR spectroscopy is noted and explained. Good agreement between experimental and theoretical line shape (and thus mass resolution) is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Petroleomics: The Next Grand Challenge for Chemical Analysis
Marshall, A. G., & Rodgers, R. P. (2004) · Accounts of Chemical Research · doi:10.1021/ar020177t · Cited by 817
Self-citation40 years of Fourier transform ion cyclotron resonance mass spectrometry
Marshall, A. G., & Chen, T. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.06.034 · Cited by 70
Self-citationValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Self-citation
Metadata
- Authors
- Marshall, A. G., Comisarow, M. B., & Parisod, G.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1979-12-01
- Volume
- 71
- Issue
- 11
- Pages
- 4434-4444
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W1965354795
- Cited by
- 165
- References
- 0
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relaxation and spectral line shape in Fourier transform ion resonance spectroscopy. https://app.cochat.ai/papers/10.1063/1.438196
- The paper
- Marshall, A. G., Comisarow, M. B., & Parisod, G. (1979). Relaxation and spectral line shape in Fourier transform ion resonance spectroscopy. The Journal of Chemical Physics. https://doi.org/10.1063/1.438196
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.