Density-dependent separation of encapsulated cells in a microfluidic channel by using a standing surface acoustic wave
Open accessThe DOI matches its Crossref record.
Abstract
This study presents a method for density-based separation of monodisperse encapsulated cells using a standing surface acoustic wave (SSAW) in a microchannel. Even though monodisperse polymer beads can be generated by the state-of-the-art technology in microfluidics, the quantity of encapsulated cells cannot be controlled precisely. In the present study, mono-disperse alginate beads in a laminar flow can be separated based on their density using acoustophoresis. A mixture of beads of equal sizes but dissimilar densities was hydrodynamically focused at the entrance and then actively driven toward the sidewalls by a SSAW. The lateral displacement of a bead is proportional to the density of the bead, i.e., the number of encapsulated cells in an alginate bead. Under optimized conditions, the recovery rate of a target bead group (large-cell-quantity alginate beads) reached up to 97% at a rate of 2300 beads per minute. A cell viability test also confirmed that the encapsulated cells were hardly damaged by the acoustic force. Moreover, cell-encapsulating beads that were cultured for 1 day were separated in a similar manner. In conclusion, this study demonstrated that a SSAW can successfully separate monodisperse particles by their density. With the present technique for separating cell-encapsulating beads, the current cell engineering technology can be significantly advanced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Surface Acoustic Wave Microfluidics
Yeo, L. Y., & Friend, J. R. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141418 · Cited by 561
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Acoustofluidic separation of cells and particles
Wu, M., Ozcelik, A., Rufo, J., Wang, Z., Fang, R., & Jun Huang, T. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0064-3 · Cited by 453
Metadata
- Authors
- Nam, J., Lim, H., Kim, C., Yoon Kang, J., & Shin, S.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2012-05-16
- Volume
- 6
- Issue
- 2
- Pages
- 24120-2412010
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2014899391
- Cited by
- 133
- References
- 0
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Density-dependent separation of encapsulated cells in a microfluidic channel by using a standing surface acoustic wave. https://app.cochat.ai/papers/10.1063/1.4718719
- The paper
- Nam, J., Lim, H., Kim, C., Yoon Kang, J., & Shin, S. (2012). Density-dependent separation of encapsulated cells in a microfluidic channel by using a standing surface acoustic wave. Biomicrofluidics. https://doi.org/10.1063/1.4718719
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.