The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Dynamics of magnetic nanoparticle in a viscous liquid: Application to magnetic nanoparticle hyperthermia
Abstract
It is shown that the magnetic dynamics of an assembly of nanoparticles dispersed in a viscous liquid differs significantly from the behavior of the same assembly of nanoparticles immobilized in a solid matrix. For an assembly of magnetic nanoparticles in a liquid two characteristic mode for stationary magnetization oscillations are found that can be called the viscous and magnetic modes, respectively. In the viscous mode, which occurs for small amplitude of the alternating magnetic field H0 as compared to the particle anisotropy field Hk, the particle rotates in the liquid as a whole. In a stationary motion the unit magnetization vector and the director, describing the spatial orientation of the particle, move in unison, but the phase of oscillations of these vectors is shifted relative to that of the alternating magnetic field. Therefore, for the viscous mode the energy absorption is mainly due to viscous losses associated with the particle rotation in the liquid. In the opposite regime, H0 ≥ Hk, the director oscillates only slightly near the external magnetic field direction, whereas the unit magnetization vector sharply jumps between magnetic potential wells. Thus, a complete orientation of the assembly of nanoparticles in the liquid occurs in the alternating magnetic field of sufficient amplitude. As a result, large specific absorption rates, of the order of 1 kW/g, can be obtained for an assembly of magnetic nanoparticles in viscous liquid in the transient, H0 ∼ 0.5Hk, and magnetic modes at moderate frequency and alternating magnetic field amplitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Fluctuations of a Single-Domain Particle
Brown, W. F. (1963) · Physical Review · doi:10.1103/physrev.130.1677 · Cited by 3,374
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Cited by
Thermal fluctuations of magnetic nanoparticles: Fifty years after Brown
Coffey, W. T., & Kalmykov, Y. P. (2012) · Journal of Applied Physics · doi:10.1063/1.4754272 · Cited by 282
Improving the Heating Efficiency of Iron Oxide Nanoparticles by Tuning Their Shape and Size
Nemati, Z., Alonso, J., Rodrigo, I., Das, R., Garaio, E., García, J. Á., Orue, I., Phan, M.-H., & Srikanth, H. (2018) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.7b10528 · Cited by 256
Metadata
- Authors
- Usov, N. A., & Liubimov, B. Y.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2012-07-15
- Volume
- 112
- Issue
- 2
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2071503693
- Cited by
- 197
- References
- 2
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamics of magnetic nanoparticle in a viscous liquid: Application to magnetic nanoparticle hyperthermia. https://app.cochat.ai/papers/10.1063/1.4737126
- The paper
- Usov, N. A., & Liubimov, B. Y. (2012). Dynamics of magnetic nanoparticle in a viscous liquid: Application to magnetic nanoparticle hyperthermia. Journal of Applied Physics. https://doi.org/10.1063/1.4737126
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.