Portable double-sided laser-heating system for Mössbauer spectroscopy and X-ray diffraction experiments at synchrotron facilities with diamond anvil cells
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The diamond anvil cell (DAC) technique coupled with laser heating is a major method for studying materials statically at multimegabar pressures and at high temperatures. Recent progress in experimental techniques, especially in high-pressure single crystal X-ray diffraction, requires portable laser heating systems which are able to heat and move the DAC during data collection. We have developed a double-sided laser heating system for DACs which can be mounted within a rather small (∼0.1 m2) area and has a weight of ∼12 kg. The system is easily transferable between different in-house or synchrotron facilities and can be assembled and set up within a few hours. The system was successfully tested at the High Pressure Station of White Beam (ID09a) and Nuclear Resonance (ID18) beamlines of the European Synchrotron Radiation Facility. We demonstrate examples of application of the system to a single crystal X-ray diffraction investigation of (Mg0.87,Fe3+0.09,Fe2+0.04)(Si0.89,Al0.11)O3 perovskite (ID09a) and a Synchrotron Mössbauer Source (SMS) study of (Mg0.8Fe0.2)O ferropericlase (ID18).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kantor, I. Y., Dubrovinsky, L. S., & McCammon, C. A. (2006) · Physical Review B · doi:10.1103/physrevb.73.100101 · Cited by 72
Self-citationSingle-crystal X-ray diffraction at megabar pressures and temperatures of thousands of degrees
Dubrovinsky, L., Boffa-Ballaran, T., Glazyrin, K., Kurnosov, A., Frost, D., Merlini, M., Hanfland, M., Prakapenka, V. B., Schouwink, P., Pippinger, T., et al. (2010) · High Pressure Research · doi:10.1080/08957959.2010.534092 · Cited by 68
Self-citation
Cited by
Stability of iron-bearing carbonates in the deep Earth’s interior
Cerantola, V., Bykova, E., Kupenko, I., Merlini, M., Ismailova, L., McCammon, C., Bykov, M., Chumakov, A. I., Petitgirard, S., Kantor, I., et al. (2017) · Nature Communications · doi:10.1038/ncomms15960 · Cited by 120
Self-citationKupenko, I., McCammon, C., Sinmyo, R., Cerantola, V., Potapkin, V., Chumakov, A. I., Kantor, A., Rüffer, R., & Dubrovinsky, L. (2015) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2015.04.027 · Cited by 36
Self-citationChariton, S., Cerantola, V., Ismailova, L., Bykova, E., Bykov, M., Kupenko, I., McCammon, C., & Dubrovinsky, L. (2018) · Physics and Chemistry of Minerals · doi:10.1007/s00269-017-0902-5 · Cited by 13
Self-citation
Metadata
- Authors
- Kupenko, I., Dubrovinsky, L., Dubrovinskaia, N., McCammon, C., Glazyrin, K., Bykova, E., Ballaran, T. B., Sinmyo, R., Chumakov, A. I., Potapkin, V., Kantor, A., Rüffer, R., Hanfland, M., Crichton, W., & Merlini, M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2012-12-01
- Volume
- 83
- Issue
- 12
- Pages
- 124501-124501
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2020142341
- Cited by
- 62
- References
- 2
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.