Micro-fabricated stylus ion trap
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An electroformed, three-dimensional stylus Paul trap was designed to confine a single atomic ion for use as a sensor to probe the electric-field noise of proximate surfaces. The trap was microfabricated with the UV-LIGA technique to reduce the distance of the ion from the surface of interest. We detail the fabrication process used to produce a 150 μm tall stylus trap with feature sizes of 40 μm. We confined single, laser-cooled, 25Mg+ ions with lifetimes greater than 2 h above the stylus trap in an ultra-high-vacuum environment. After cooling a motional mode of the ion at 4 MHz close to its ground state (⟨n⟩ = 0.34 ± 0.07), the heating rate of the trap was measured with Raman sideband spectroscopy to be 387 ± 15 quanta/s at an ion height of 62 μm above the stylus electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental issues in coherent quantum-state manipulation of trapped atomic ions
Wineland, D. J., Monroe, C., Itano, W. M., Leibfried, D., King, B. E., & Meekhof, D. M. (1998) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.103.019 · Cited by 1,497
Self-citationMinimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationHite, D. A., Colombe, Y., Wilson, A. C., Brown, K. R., Warring, U., Jördens, R., Jost, J. D., McKay, K. S., Pappas, D. P., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.103001 · Cited by 176
Self-citation
Cited by
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
Surface science motivated by heating of trapped ions from the quantum ground state
Hite, D. A., McKay, K. S., & Pappas, D. P. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac2c2c · Cited by 11
Self-citationOpinion: Democratizing Spin Qubits
Tahan, C. (2021) · Quantum · doi:10.22331/q-2021-11-18-584 · Cited by 9
Measurement of electric-field noise from interchangeable samples with a trapped-ion sensor
McKay, K. S., Hite, D. A., Kent, P. D., Kotler, S., Leibfried, D., Slichter, D. H., Wilson, A. C., & Pappas, D. P. (2021) · Physical Review A · doi:10.1103/physreva.104.052610 · Cited by 8
Self-citation
Metadata
- Authors
- Arrington, C. L., McKay, K. S., Baca, E. D., Coleman, J. J., Colombe, Y., Finnegan, P., Hite, D. A., Hollowell, A. E., Jördens, R., Jost, J. D., Leibfried, D., Rowen, A. M., Warring, U., Weides, M., Wilson, A. C., Wineland, D. J., & Pappas, D. P.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2013-08-01
- Volume
- 84
- Issue
- 8
- Pages
- 085001-085001
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2068521959
- Cited by
- 25
- References
- 3
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.