The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Direct measurement of ion evaporation kinetics from electrified liquid surfaces
Abstract
When concentrated solutions of NaI in formamide with electrical conductivities K larger than 1.1 S/m are electrosprayed from a Taylor cone-jet in a vacuum, ions are evaporated at substantial rates from the surface of the meniscus and the drops. This constitutes a new source of ions and nanoparticles, where the relative importance of these two contributions is adjustable. The currents of ions are measured independently from those associated with drops by a combination of stopping voltage analysis and preferential scattering in a gas background. The magnitude E of the electric field at the surface of the drops and at the apex of the cone-jet is controlled through the electrical conductivity K of the liquid and its flow rate Q through the jet. E is related through available scaling laws for Taylor cone-jets to the ratios K/Q or I/Q, where I is the current of drops emitted by the jet. Ion currents are very small or null at typical K/Q values used in the past. A relatively small initial ion current is attributed to a few particularly sharp features present, perhaps associated with small satellite drops. At still higher K/Q this first ionization source saturates, and ion evaporation from the main drops begins to dominate (E∼1 V/nm). E can then be determined with little ambiguity, and the associated ion current is also measured over a broad enough range of electric fields to determine the ionization kinetics. At still higher K/Q the ion current from the drops approaches saturation, and ion evaporation directly from the meniscus becomes dominant. The total spray current then presents the anomaly of increasing rapidly at decreasing liquid flow rate. The ion current from the meniscus can also be measured in this regime over a broad range of K/Q, with qualitative agreement with the ionization measurements from the drops. But the relation established between K/Q and E becomes suspect because ion and drop currents are now comparable. A third approach to infer the ionization rate is based on the related disappearance of Coulomb explosions of the drops above a critical K/Q. These results are congruent with the model of Iribarne and Thomson, with an activation barrier for ion evaporation equal to 1.7 eV−(e3E/4πε0)1/2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
The Fluid Dynamics of Taylor Cones
Fernández de la Mora, J. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110159 · Cited by 594
Self-citationRomero-Sanz, I., Bocanegra, R., Fernandez de la Mora, J., & Gamero-Castaño, M. (2003) · Journal of Applied Physics · doi:10.1063/1.1598281 · Cited by 257
Self-citation
Metadata
- Authors
- Gamero-Castaño, M., & Fernández de la Mora, J.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 2000-07-08
- Volume
- 113
- Issue
- 2
- Pages
- 815-832
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2171781071
- Cited by
- 172
- References
- 1
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct measurement of ion evaporation kinetics from electrified liquid surfaces. https://app.cochat.ai/papers/10.1063/1.481857
- The paper
- Gamero-Castaño, M., & Fernández de la Mora, J. (2000). Direct measurement of ion evaporation kinetics from electrified liquid surfaces. The Journal of Chemical Physics. https://doi.org/10.1063/1.481857
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.