High-resolution multi-heterodyne spectroscopy based on Fabry-Perot quantum cascade lasers
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this Letter, we present a method of performing broadband mid-infrared spectroscopy with conventional, free-running, continuous wave Fabry-Perot quantum cascade lasers (FP-QCLs). The measurement method is based on multi-heterodyne down-conversion of optical signals. The sample transmission spectrum probed by one multi-mode FP-QCL is down-converted to the radio-frequency domain through an optical multi-heterodyne process using a second FP-QCL as the local oscillator. Both a broadband multi-mode spectral measurement as well as high-resolution (∼15 MHz) spectroscopy of molecular absorption are demonstrated and show great potential for development of high performance FP-laser-based spectrometers for chemical sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Coherent sampling of active mode-locked terahertz quantum cascade lasers and frequency synthesis
Barbieri, S., Ravaro, M., Gellie, P., Santarelli, G., Manquest, C., Sirtori, C., Khanna, S. P., Linfield, E. H., & Davies, A. G. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.49 · Cited by 223
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
“Nevertheless, demonstrations with freerunning combs have been important as basic proof-of-principle experiments, for example, the first demonstration of DCS by Keilmann and coworkers [2,3], cavity-enhanced DCS [14], and many demonstrations with novel comb sources in the mid-IR and far-IR [16,28,33,35,37,38,41,48,51,93…”
InfluentialDual-comb spectroscopy based on quantum-cascade-laser frequency combs
Villares, G., Hugi, A., Blaser, S., & Faist, J. (2014) · Nature Communications · doi:10.1038/ncomms6192 · Cited by 529
Silicon-chip-based mid-infrared dual-comb spectroscopy
Yu, M., Okawachi, Y., Griffith, A. G., Picqué, N., Lipson, M., & Gaeta, A. L. (2018) · Nature Communications · doi:10.1038/s41467-018-04350-1 · Cited by 416
Octave-spanning semiconductor laser
Rösch, M., Scalari, G., Beck, M., & Faist, J. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.279 · Cited by 280
Quantum Cascade Laser Frequency Combs
Faist, J., Villares, G., Scalari, G., Rösch, M., Bonzon, C., Hugi, A., & Beck, M. (2016) · Nanophotonics · doi:10.1515/nanoph-2016-0015 · Cited by 222
Metadata
- Authors
- Wang, Y., Soskind, M. G., Wang, W., & Wysocki, G.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2014-01-20
- Volume
- 104
- Issue
- 3
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2061026175
- Cited by
- 78
- References
- 3
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution multi-heterodyne spectroscopy based on Fabry-Perot quantum cascade lasers. https://app.cochat.ai/papers/10.1063/1.4862756
- The paper
- Wang, Y., Soskind, M. G., Wang, W., & Wysocki, G. (2014). High-resolution multi-heterodyne spectroscopy based on Fabry-Perot quantum cascade lasers. Applied Physics Letters. https://doi.org/10.1063/1.4862756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.