CoChat

Rapid thermal processing chamber for in-situ x-ray diffraction

Ahmad, Md. Imteyaz, Van Campen, Douglas G., Fields, Jeremy D., Yu, Jiafan, Pool, Vanessa L., Parilla, Philip A., Ginley, David S., Van Hest, Maikel F. A. M., Toney, Michael F. · 2015 · Review of Scientific Instruments

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Rapid thermal processing (RTP) is widely used for processing a variety of materials, including electronics and photovoltaics. Presently, optimization of RTP is done primarily based on ex-situ studies. As a consequence, the precise reaction pathways and phase progression during the RTP remain unclear. More awareness of the reaction pathways would better enable process optimization and foster increased adoption of RTP, which offers numerous advantages for synthesis of a broad range of materials systems. To achieve this, we have designed and developed a RTP instrument that enables real-time collection of X-ray diffraction data with intervals as short as 100 ms, while heating with ramp rates up to 100 °Cs−1, and with a maximum operating temperature of 1200 °C. The system is portable and can be installed on a synchrotron beamline. The unique capabilities of this instrument are demonstrated with in-situ characterization of a Bi2O3-SiO2 glass frit obtained during heating with ramp rates 5 °C s−1 and 100 °C s−1, revealing numerous phase changes.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.4904848

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Research works printed but not linked: 1

  1. 1983, Physical Metallurgy, 852

Cited by

See all 20

Metadata

Authors
Ahmad, M. I., Van Campen, D. G., Fields, J. D., Yu, J., Pool, V. L., Parilla, P. A., Ginley, D. S., Van Hest, M. F. A. M., & Toney, M. F.
Affiliations
  • SLAC National Accelerator Laboratory (US)
  • 1SSRL, SLAC National Accelerator Laboratory, 2575, Sand Hill Road, Menlo Park, California 94025, USA
  • National Laboratory of the Rockies (US)
Venue
Review of Scientific Instruments
Published
2015-01-01
Volume
86
Issue
1
Pages
013902-013902
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2092275834
Cited by
18
References
17
Citations by year
2026: 3 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 2
FWCI
0.95
Type
journal article
Language
en
Open access
closed
Locations
  • Review of Scientific Instruments (publishedVersion)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Funders
U.S. Department of Energy (DE-AC02-76SF00515, DE-EE0005951)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › X-ray Diffraction in Crystallography
  • Physical Sciences › Materials Science › Ceramics and Composites › Glass properties and applications
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal and Kinetic Analysis
Keywords
rapid thermal processing, in situ X-ray diffraction, reaction pathways, phase progression, high-temperature heating, synchrotron beamline instrumentation, process optimization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid thermal processing chamber for in-situ x-ray diffraction. https://app.cochat.ai/papers/10.1063/1.4904848
The paper
Ahmad, M. I., Van Campen, D. G., Fields, J. D., Yu, J., Pool, V. L., Parilla, P. A., Ginley, D. S., Van Hest, M. F. A. M., & Toney, M. F. (2015). Rapid thermal processing chamber for in-situ x-ray diffraction. Review of Scientific Instruments. https://doi.org/10.1063/1.4904848

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.