Microfluidic based high throughput synthesis of lipid-polymer hybrid nanoparticles with tunable diameters
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Core-shell hybrid nanoparticles (NPs) for drug delivery have attracted numerous attentions due to their enhanced therapeutic efficacy and good biocompatibility. In this work, we fabricate a two-stage microfluidic chip to implement a high-throughput, one-step, and size-tunable synthesis of mono-disperse lipid-poly (lactic-co-glycolic acid) NPs. The size of hybrid NPs is tunable by varying the flow rates inside the two-stage microfluidic chip. To elucidate the mechanism of size-controllable generation of hybrid NPs, we observe the flow field in the microchannel with confocal microscope and perform the simulation by a numerical model. Both the experimental and numerical results indicate an enhanced mixing effect at high flow rate, thus resulting in the assembly of small and mono-disperse hybrid NPs. In vitro experiments show that the large hybrid NPs are more likely to be aggregated in serum and exhibit a lower cellular uptake efficacy than the small ones. This microfluidic chip shows great promise as a robust platform for optimization of nano drug delivery system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
He, C., Hu, Y., Yin, L., Tang, C., & Yin, C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.065 · Cited by 2,607
Jain, R. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00115-0 · Cited by 2,214
Yin Win, K., & Feng, S.-S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.050 · Cited by 1,452
Microfluidic Platform for Controlled Synthesis of Polymeric Nanoparticles
Karnik, R., Gu, F., Basto, P., Cannizzaro, C., Dean, L., Kyei-Manu, W., Langer, R., & Farokhzad, O. C. (2008) · Nano Letters · doi:10.1021/nl801736q · Cited by 887
PLGA Nanoparticles in Drug Delivery: The State of the Art;
Bala, I., Hariharan, S., & Kumar, M. R. (2004) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v21.i5.20 · Cited by 739
A microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Cited by
Lipid Nanoparticles for Drug Delivery
Xu, L., Wang, X., Liu, Y., Yang, G., Falconer, R. J., & Zhao, C.-X. (2022) · Advanced NanoBiomed Research · doi:10.1002/anbr.202100109 · Cited by 545
Huang, T.-Y., Huang, G.-L., Zhang, C.-Y., Zhuang, B.-W., Liu, B.-X., Su, L.-Y., Ye, J.-Y., Xu, M., Kuang, M., & Xie, X.-Y. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00001 · Cited by 361
Why microfluidics? Merits and trends in chemical synthesis
Liu, Y., & Jiang, X. (2017) · Lab on a Chip · doi:10.1039/c7lc00627f · Cited by 291
Self-citationMicrofluidic Nanoparticles for Drug Delivery
Liu, Y., Yang, G., Hui, Y., Ranaweera, S., & Zhao, C. (2022) · Small · doi:10.1002/smll.202106580 · Cited by 277
Ma, J., Lee, S. M.-Y., Yi, C., & Li, C.-W. (2017) · Lab on a Chip · doi:10.1039/c6lc01049k · Cited by 275
Metadata
- Authors
- Feng, Q., Zhang, L., Liu, C., Li, X., Hu, G., Sun, J., & Jiang, X.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-06-23
- Volume
- 9
- Issue
- 5
- Pages
- 052604-052604
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W1502452493
- Cited by
- 105
- References
- 7
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.