Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.

Techniques for precise energy calibration of particle pixel detectors

Open access
Kroupa, M., Campbell-Ricketts, T., Bahadori, A., Empl, A. · 2017 · Review of Scientific Instruments

Abstract

We demonstrate techniques to improve the accuracy of the energy calibration of Timepix pixel detectors, used for the measurement of energetic particles. The typical signal from such particles spreads among many pixels due to charge sharing effects. As a consequence, the deposited energy in each pixel cannot be reconstructed unless the detector is calibrated, limiting the usability of such signals for calibration. To avoid this shortcoming, we calibrate using low energy X-rays. However, charge sharing effects still occur, resulting in part of the energy being deposited in adjacent pixels and possibly lost. This systematic error in the calibration process results in an error of about 5% in the energy measurements of calibrated devices. We use FLUKA simulations to assess the magnitude of charge sharing effects, allowing a corrected energy calibration to be performed on several Timepix pixel detectors and resulting in substantial improvement in energy deposition measurements. Next, we address shortcomings in calibration associated with the huge range (from kiloelectron-volts to megaelectron-volts) of energy deposited per pixel which result in a nonlinear energy response over the full range. We introduce a new method to characterize the non-linear response of the Timepix detectors at high input energies. We demonstrate improvement using a broad range of particle types and energies, showing that the new method reduces the energy measurement errors, in some cases by more than 90%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.4978281

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 26

Metadata

Authors
Kroupa, M., Campbell-Ricketts, T., Bahadori, A., & Empl, A.
Affiliations
Kansas State University (US)
Venue
Review of Scientific Instruments
Published
2017-03-01
Volume
88
Issue
3
Pages
033301-033301
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2596431638
Cited by
26
References
19
Citations by year
2026: 1 · 2024: 4 · 2023: 5 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 4 · 2018: 6 · 2017: 1
FWCI
1.82
Type
journal article
Language
en
Open access
Locations
  • Review of Scientific Instruments (publishedVersion)
  • PubMed (publishedVersion)
  • K-State Research Exchange (Kansas State University) (submittedVersion)
Funders
Johnson Space Center (Bioastronautics, Human Health and Performance Contract)
Topics
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle Detector Development and Performance
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Detection and Scintillator Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
Keywords
energy calibration, charge sharing, low-energy X-rays, FLUKA simulation, energy deposition, energetic particles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Techniques for precise energy calibration of particle pixel detectors. https://app.cochat.ai/papers/10.1063/1.4978281
The paper
Kroupa, M., Campbell-Ricketts, T., Bahadori, A., & Empl, A. (2017). Techniques for precise energy calibration of particle pixel detectors. Review of Scientific Instruments. https://doi.org/10.1063/1.4978281

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.