Abstract
The combination of magnetism and microscale fluid flow has opened up a new era for handling and manipulation of samples in microfluidics. In particular, magnetophoresis, the migration of particles in a magnetic field, is extremely attractive for microfluidic handling due to its contactless nature, independence of ionic concentration, and lack of induced heating. The present paper focuses on recent advances and current challenges of magnetophoresis and highlights the key parameters affecting the manipulation of particles by magnetophoresis. The magnetic field is discussed according to their relative motion to the sample as stationary and dynamic fields. The migration of particles is categorized as positive and negative magnetophoresis. The applications of magnetophoresis are discussed according to the basic manipulation tasks such as mixing, separation, and trapping of particles or cells. Finally, the paper highlights the limitations of current approaches and provides the future perspective for this research area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Self-citationPamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
CLONAL GROWTH OF MAMMALIAN CELLS IN VITRO
Puck, T. T., Marcus, P. I., & Cieciura, S. J. (1956) · The Journal of Experimental Medicine · doi:10.1084/jem.103.2.273 · Cited by 1,127
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Suresh, S., Spatz, J., Mills, J. P., Micoulet, A., Dao, M., Lim, C. T., Beil, M., & Seufferlein, T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.001 · Cited by 878
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Research works printed but not linked: 4
- 2013, Ferrohydrodynamics
- 2006, Classical Electromagnetic Theory
- 1998, Incompressible Flow and the Finite Element Method, Volume 1: Advection-diffusion and Isothermal Laminar Flow
- 1987, Fluid mechanics, Volume 6: Course of Theoretical Physics
Cited by
A Review on Deterministic Lateral Displacement for Particle Separation and Detection
Salafi, T., Zhang, Y., & Zhang, Y. (2019) · Nano-Micro Letters · doi:10.1007/s40820-019-0308-7 · Cited by 229
Chai, Z., Childress, A., & Busnaina, A. A. (2022) · ACS Nano · doi:10.1021/acsnano.2c07910 · Cited by 170
Descamps, L., Roy, D. L., & Deman, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23041981 · Cited by 164
Xuan, X. S. (2019) · Electrophoresis · doi:10.1002/elps.201900048 · Cited by 144
Basic Principles and Recent Advances in Magnetic Cell Separation
Frénéa‐Robin, M., & Marchalot, J. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8010011 · Cited by 133
Metadata
- Authors
- Munaz, A., Shiddiky, M. J. A., & Nguyen, N.-T.
- Affiliations
- Griffith University (AU)
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2018-05-01
- Volume
- 12
- Issue
- 3
- Pages
- 031501-031501
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC6013300
- OpenAlex
- W2809567011
- Cited by
- 164
- References
- 114
- Citations by year
- 2026: 16 · 2025: 24 · 2024: 19 · 2023: 27 · 2022: 21 · 2021: 24 · 2020: 19 · 2019: 12 · 2018: 2
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biomicrofluidics (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Griffith Research Online (submittedVersion)
- Funders
- Australian Research Council (DP180100055)
- National Institutes of Health
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- magnetophoresis, particle manipulation, magnetic field, particle separation, cell trapping, mixing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.