A Review on Deterministic Lateral Displacement for Particle Separation and Detection
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
The separation and detection of particles in suspension are essential for a wide spectrum of applications including medical diagnostics. In this field, microfluidic deterministic lateral displacement (DLD) holds a promise due to the ability of continuous separation of particles by size, shape, deformability, and electrical properties with high resolution. DLD is a passive microfluidic separation technique that has been widely implemented for various bioparticle separations from blood cells to exosomes. DLD techniques have been previously reviewed in 2014. Since then, the field has matured as several physics of DLD have been updated, new phenomena have been discovered, and various designs have been presented to achieve a higher separation performance and throughput. Furthermore, some recent progress has shown new clinical applications and ability to use the DLD arrays as a platform for biomolecules detection. This review provides a thorough discussion on the recent progress in DLD with the topics based on the fundamental studies on DLD models and applications for particle separation and detection. Furthermore, current challenges and potential solutions of DLD are also discussed. We believe that a comprehensive understanding on DLD techniques could significantly contribute toward the advancements in the field for various applications. In particular, the rapid, low-cost, and high-throughput particle separation and detection with DLD have a tremendous impact for point-of-care diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Microfluidic, marker-free isolation of circulating tumor cells from blood samples
Karabacak, N. M., Spuhler, P. S., Fachin, F., Lim, E. J., Pai, V., Ozkumur, E., Martel, J. M., Kojic, N., Smith, K., Chen, P.-I., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.044 · Cited by 760
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Nanoscale lateral displacement arrays for the separation of exosomes and colloids down to 20 nm
Wunsch, B. H., Smith, J. T., Gifford, S. M., Wang, C., Brink, M., Bruce, R. L., Austin, R. H., Stolovitzky, G., & Astier, Y. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.134 · Cited by 582
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Deterministic lateral displacement for particle separation: a review
McGrath, J. S., Jimenez, M., & Bridle, H. L. (2014) · Lab on a Chip · doi:10.1039/c4lc00939h · Cited by 441
Critical particle size for fractionation by deterministic lateral displacement
Inglis, D. W., Davis, J. A., Austin, R. H., & Sturm, J. C. (2006) · Lab on a Chip · doi:10.1039/b515371a · Cited by 421
Particle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
Cited by
Shirejini, S. Z., & Inci, F. (2022) · Biotechnology Advances · doi:10.1016/j.biotechadv.2021.107814 · Cited by 187
Microfluidic Technology for the Isolation and Analysis of Exosomes
Wu, Y., Wang, Y., Lu, Y., Luo, X., Huang, Y., Xie, T., Pilarsky, C., Dang, Y., & Zhang, J. (2022) · Micromachines · doi:10.3390/mi13101571 · Cited by 91
Metadata
- Authors
- Salafi, T., Zhang, Y., & Zhang, Y.
- Venue
- Nano-Micro Letters
- Published
- 2019-09-17
- Volume
- 11
- Issue
- 1
- Pages
- 77-77
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W2973761847
- Cited by
- 229
- References
- 48
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review on Deterministic Lateral Displacement for Particle Separation and Detection. https://app.cochat.ai/papers/10.1007/s40820-019-0308-7
- The paper
- Salafi, T., Zhang, Y., & Zhang, Y. (2019). A Review on Deterministic Lateral Displacement for Particle Separation and Detection. Nano-Micro Letters. https://doi.org/10.1007/s40820-019-0308-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.