A cell lines derived microfluidic liver model for investigation of hepatotoxicity induced by drug-drug interaction
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The poor metabolic ability of cell lines fails to meet the requirements of an in vitro model for drug interaction testing which is crucial for the development or clinical application of drugs. Herein, we describe a liver sinusoid-on-a-chip device composed of four kinds of transformed cell lines (HepG2 cells, LX-2 cells, EAhy926 cells, and U937 cells) that were ordered in a physiological distribution with artificial liver blood flow and biliary efflux flowing in the opposite direction. This microfluidic device applied three-dimensional culturing of HepG2 cells with high density (107 ml−1), forming a tightly connected monolayer of EAhy926 cells and achieving the active transport of drugs in HepG2 cells. Results showed that the device maintained synthetic and secretory functions, preserved cytochrome P450 1A1/2 and uridine diphosphate glucuronyltransferase enzymatic activities, as well as sensitivity of drug metabolism. The cell lines derived device enables the investigation of a drug-drug interaction study. We used it to test the hepatotoxicity of acetaminophen and the following combinations: “acetaminophen + rifampicin,” “acetaminophen + omeprazole,” and “acetaminophen + ciprofloxacin.” The variations in hepatotoxicity of the combinations compared to acetaminophen alone, which is not found in a 96-well plate model, in the device were −17.15%, 14.88%, and −19.74%. In addition, this result was similar to the one tested by the classical primary hepatocyte plate model (−13.22%, 13.51%, and −15.81%). Thus, this cell lines derived liver model provides an alternative to investigate drug hepatotoxicity, drug-drug interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Esch, M. B., Mahler, G. J., Stokol, T., & Shuler, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00371c · Cited by 281
Mimicking liver sinusoidal structures and functions using a 3D-configured microfluidic chip
Du, Y., Li, N., Yang, H., Luo, C., Gong, Y., Tong, C., Gao, Y., Lü, S., & Long, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01374k · Cited by 241
3D microfluidic liver cultures as a physiological preclinical tool for hepatitis B virus infection
Ortega-Prieto, A. M., Skelton, J. K., Wai, S. N., Large, E., Lussignol, M., Vizcay-Barrena, G., Hughes, D., Fleck, R. A., Thursz, M., Catanese, M. T., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02969-8 · Cited by 236
Long‐term maintenance of a microfluidic 3D human liver sinusoid
Prodanov, L., Jindal, R., Bale, S. S., Hegde, M., McCarty, W. J., Golberg, I., Bhushan, A., Yarmush, M. L., & Usta, O. B. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25700 · Cited by 214
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Hepatic 3D spheroid models for the detection and study of compounds with cholestatic liability
Hendriks, D. F. G., Fredriksson Puigvert, L., Messner, S., Mortiz, W., & Ingelman-Sundberg, M. (2016) · Scientific Reports · doi:10.1038/srep35434 · Cited by 156
Cited by
Drug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
“[70] constructed a hepatic sinusoidal chip device consisting of four transformed cell lines and perfused it with a peristaltic pump.”
Self-citationA critical perspective on 3D liver models for drug metabolism and toxicology studies
Serras, A. S., Rodrigues, J. S., Cipriano, M., Rodrigues, A. V., Oliveira, N. G., & Miranda, J. P. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.626805 · Cited by 138
Primary Hepatocyte Isolation and Cultures: Technical Aspects, Challenges and Advancements
Kaur, I., Vasudevan, A., Rawal, P., Tripathi, D. M., Ramakrishna, S., Kaur, S., & Sarin, S. K. (2023) · Bioengineering · doi:10.3390/bioengineering10020131 · Cited by 64
“When exposed to hepatotoxicity-inducing compounds, cells grown in this technique demonstrated greater sensitivity to hepatotoxicity than cells grown in well plate-based static cultures [79].”
Liver–heart on chip models for drug safety
Ferrari, E., & Rasponi, M. (2021) · APL Bioengineering · doi:10.1063/5.0048986 · Cited by 53
Metadata
- Authors
- Deng, J., Zhang, X., Chen, Z., Luo, Y., Lu, Y., Liu, T., Wu, Z., Jin, Y., Zhao, W., & Lin, B.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2019-03-01
- Volume
- 13
- Issue
- 2
- Pages
- 024101-024101
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2921915346
- Cited by
- 70
- References
- 11
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A cell lines derived microfluidic liver model for investigation of hepatotoxicity induced by drug-drug interaction. https://app.cochat.ai/papers/10.1063/1.5070088
- The paper
- Deng, J., Zhang, X., Chen, Z., Luo, Y., Lu, Y., Liu, T., Wu, Z., Jin, Y., Zhao, W., & Lin, B. (2019). A cell lines derived microfluidic liver model for investigation of hepatotoxicity induced by drug-drug interaction. Biomicrofluidics. https://doi.org/10.1063/1.5070088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.