CoChat

Electromagnetic and mechanical characterization of a flexible coil for transcranial magnetic stimulation

Open access

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Transcranial magnetic stimulation is a painless and noninvasive method for treating brain disorders. The coil-geometries that match the head topologies achieve more effective stimulation, however it is difficult for a rigid coil to fit the skulls of all patients. We propose and develop a rubber-like flexible coil that can be shaped into different geometries to reduce the inter-individual variabilities in its clinical use. The main challenge is attributed to the fact that the external bending and induced Lorentzian forces cause coil deformation and fatigue. Herein, we investigated the influence of bending on the electromagnetic characteristics of the flexible coil. The magnetic field distribution was calculated and measured using a search coil. The induced Lorentzian force was calculated and the induced eddy current density was simulated using the scalar potential finite difference (SPFD) method. For a mechanical characterization, we fixed the center of the coil, and external bending forces were applied on the two wings of the coils, while Lorentzian forces were applied in a direction normal to the side wall of the wire groove. Fatigue analyses of these forces were also conducted. The results show that the eddy current density induced in the brain by the flexible coil was significantly higher compared to that of the figure-eight and butterfly coils. Fatigue analyses show that the bending force required to achieve a close coil fit on the human head and the generated Lorentzian force would not lead to fatigue problem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.5080148

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 5

  1. 1993, Electroencephalogr Clin Neurophysiol X, 15
  2. 2016, IEEE Trans Magnetics, 52, 1
  3. 2013, Funct Neurol Rehabil Ergon, 3, 275
  4. 2007, Introduction to Electrodynamics
  5. 2013, Int Res J Eng Technol (IRJET), 3, 2250

Cited by

See all 6

Metadata

Authors
Liu, M., Tuovinen, P. H., Kawasaki, Y., Yedeas, M. A., Saitoh, Y., & Sekino, M.
Affiliations
The University of Tokyo (JP)
Venue
AIP Advances
Published
2019-03-01
Volume
9
Issue
3
ISSN
2158-3226 (ISSN-L)
OpenAlex
W2945403051
Cited by
6
References
9
Citations by year
2022: 2 · 2021: 3 · 2020: 1
FWCI
0.66
Type
journal article
Language
en
Open access
Licence
Locations
  • AIP Advances (publishedVersion, cc-by)
  • Aaltodoc (Aalto University) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Teijin Pharma
Topics
  • Life Sciences › Neuroscience › Neurology › Transcranial Magnetic Stimulation Studies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
Keywords
transcranial magnetic stimulation, flexible coils, eddy current density, magnetic field distribution, coil deformation, figure-of-eight coil, interindividual variability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electromagnetic and mechanical characterization of a flexible coil for transcranial magnetic stimulation. https://app.cochat.ai/papers/10.1063/1.5080148
The paper
Liu, M., Tuovinen, P. H., Kawasaki, Y., Yedeas, M. A., Saitoh, Y., & Sekino, M. (2019). Electromagnetic and mechanical characterization of a flexible coil for transcranial magnetic stimulation. AIP Advances. https://doi.org/10.1063/1.5080148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.