The DOI matches its Crossref record.
Application of scanning electron microscopy to determination of surface recombination velocity: GaAs
Abstract
A method is reported for the determination of the surface recombination velocity by scanning electron microscopy; this method is based on an established relationship between the effective diffusion length of the minority carriers, the penetration depth of the electron beam, and the surface recombination velocity. Values of surface recombination velocity, up to about 2.5×106 cm/sec were determined in n-type GaAs with a bulk minority-carrier lifetime of the order of 10−8–10−10 sec; in GaAs, with carrier concentrations exceeding 1018 cm−3, recombination velocity of about 3×106 cm/sec represents a saturation value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Probing ultrafast carrier and phonon dynamics in semiconductors
Othonos, A. (1998) · Journal of Applied Physics · doi:10.1063/1.367411 · Cited by 459
Wang, L., Cheaito, R., Braun, J. L., Giri, A., & Hopkins, P. E. (2016) · Review of Scientific Instruments · doi:10.1063/1.4962711 · Cited by 63
Metadata
- Authors
- Jastrzebski, L., Lagowski, J., & Gatos, H. C.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1975-11-15
- Volume
- 27
- Issue
- 10
- Pages
- 537-539
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1986870217
- Cited by
- 176
- References
- 0
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of scanning electron microscopy to determination of surface recombination velocity: GaAs. https://app.cochat.ai/papers/10.1063/1.88276
- The paper
- Jastrzebski, L., Lagowski, J., & Gatos, H. C. (1975). Application of scanning electron microscopy to determination of surface recombination velocity: GaAs. Applied Physics Letters. https://doi.org/10.1063/1.88276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.