The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Picosecond electro-optic sampling system
Abstract
We report the construction of a sensitive electro-optic sampling system for the measurement of ultrafast electrical transients. This system has a temporal resolution of lessthan 4 ps (over 100- GHz bandwidth), better than 50-μV sensitivity and potential for a temporal resolution reaching the single picosecond. Demonstrated applications are ultrafast photodetector response characterization and time resolved photoconductivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generation of optical pulses shorter than 0.1 psec by colliding pulse mode locking
Fork, R. L., Greene, B. I., & Shank, C. V. (1981) · Applied Physics Letters · doi:10.1063/1.92500 · Cited by 886
Picosecond optoelectronic switching and gating in silicon
Auston, D. H. (1975) · Applied Physics Letters · doi:10.1063/1.88079 · Cited by 768
Auston, D. H., Johnson, A. M., Smith, P. R., & Bean, J. C. (1980) · Applied Physics Letters · doi:10.1063/1.91947 · Cited by 230
Picosecond photoconductivity in radiation-damaged silicon-on-sapphire films
Smith, P. R., Auston, D. H., Johnson, A. M., & Augustyniak, W. M. (1981) · Applied Physics Letters · doi:10.1063/1.92128 · Cited by 164
An amorphous silicon photodetector for picosecond pulses
Auston, D. H., Lavallard, P., Sol, N., & Kaplan, D. (1980) · Applied Physics Letters · doi:10.1063/1.91276 · Cited by 142
Picosecond photoconductivity in germanium films
DeFonzo, A. P. (1981) · Applied Physics Letters · doi:10.1063/1.92766 · Cited by 28
Cited by
Squeezed-light–enhanced polarization interferometer
Grangier, P., Slusher, R. E., Yurke, B., & LaPorta, A. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.2153 · Cited by 493
Ultrafast electron microscopy in materials science, biology, and chemistry
King, W. E., Campbell, G. H., Frank, A., Reed, B., Schmerge, J. F., Siwick, B. J., Stuart, B. C., & Weber, P. M. (2005) · Journal of Applied Physics · doi:10.1063/1.1927699 · Cited by 345
Terahertz detectors and focal plane arrays
Rogalski, A., & Sizov, F. (2011) · Opto-Electronics Review · doi:10.2478/s11772-011-0033-3 · Cited by 345
Slusher, R. E., Grangier, P., LaPorta, A., Yurke, B., & Potasek, M. J. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.2566 · Cited by 284
Attosecond nonlinear polarization and light–matter energy transfer in solids
Sommer, A., Bothschafter, E. M., Sato, S. A., Jakubeit, C., Latka, T., Razskazovskaya, O., Fattahi, H., Jobst, M., Schweinberger, W., Shirvanyan, V., et al. (2016) · Nature · doi:10.1038/nature17650 · Cited by 252
Metadata
- Authors
- Valdmanis, J. A., Mourou, G., & Gabel, C. W.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1982-08-01
- Volume
- 41
- Issue
- 3
- Pages
- 211-212
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2011656523
- Cited by
- 359
- References
- 6
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Picosecond electro-optic sampling system. https://app.cochat.ai/papers/10.1063/1.93485
- The paper
- Valdmanis, J. A., Mourou, G., & Gabel, C. W. (1982). Picosecond electro-optic sampling system. Applied Physics Letters. https://doi.org/10.1063/1.93485
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.