Thermally tunable microring resonators based on germanium-on-insulator for mid-infrared spectrometer
Open accessAbstract
We present a thermally tunable microring resonator (MRR) implemented on a Ge-on-insulator (Ge-OI) photonic platform tailored for mid-infrared spectrometer applications. Thanks to the favorable thermo-optic effect of Ge, we characterized the optical and thermal properties of the thermally tunable Ge-OI MRR through rigorous optical and thermal numerical analyses. Building upon the simulation, a ring-shaped Au heater was successfully integrated into the Ge-OI MRR that was fabricated by using a direct wafer bonding process, followed by electron-beam lithography and dry etching techniques. Observations via thermo-reflectance microscopy revealed the temperature change within the Ge induced by heat transfer from the applied bias to the Au heater. Notably, the measured temperature change of 17 K at an applied electrical power of 181.7 mW closely aligned with the simulated values. In optical measurement, the heater-integrated Ge-OI MRR exhibited the tunability of 33.7 nm/W (0.36 nm/K) and the loaded Q factor of 21k at 4.2 µm wavelength with no bias. Hence, our demonstration of the Ge-OI tunable ring filter for mid-IR spectrometers could be a promising technology employing photonic integrated circuits for diverse applications in optical communication and spectral sensing.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Ge-OI platform provides a broad transparency window up to around 13 μm.
“providing broad transparency window up to around 13 μm36–40”
From Room-temperature waveguide-integrated photodetector using bolometric effect for mid-infrared spectroscopy applications (2025) · cites this paper as [39]
Cited by
Sorted by citations
Shim, J., Lim, J., Kim, I., Jeong, J., Kim, B. H., Kim, S. K., Geum, D.-M., & Kim, S. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-01803-3 · Cited by 31 · see citing works
“All measurements were performed at room temperature suspended-Ge 50 , Ge-on-SOI 51 , and Ge-OI 36 – 39 , making it a foundry-friendly solution with the potential of process design kits (PDKs) for large-scale MIR PICs.”
Self-citation
- Authors
- Lim, J., Shim, J., Kim, I., Kim, S. K., Geum, D.-M., & Kim, S.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Venue
- APL Photonics
- Publisher
- AIP Publishing
- Published
- 2024-10-01
- Volume
- 9
- Issue
- 10
- ISSN
- 2378-0967 (ISSN-L)
- OpenAlex
- W4403335529
- Cited by
- 7
- References
- 0
- Citations by year
- 2026: 4 · 2025: 3
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- APL Photonics (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- National Research Foundation of Korea (2023R1A2C2002777)
- KIST Institutional Program (2E32402)
- BK FOUR
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
- Keywords
- germanium-on-insulator, mid-infrared spectrometer, thermo-optic effect, direct wafer bonding, photonic integrated circuits, spectral sensing, loaded Q-factor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review