The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A novel tableted purgative for colonoscopic preparation: Efficacy and safety comparisons with Colyte and Fleet Phospho-Soda
Open accessAbstract
BACKGROUND: Currently available aqueous purgatives used before colonoscopy are poorly tolerated. We designed a tableted sodium phosphate purge that we believe will yield much greater patient acceptance. METHODS: A total of 305 outpatients undergoing routine diagnostic colonoscopy were randomized to one of three preparation groups: Colyte (100 patients), Fleet Phospho-Soda (106 patients), or sodium phosphate tablets (99 patients). Endoscopists were blinded to the type of preparation administered and answered a questionnaire regarding preparation quality. Patients answered a questionnaire designed to analyze tolerability. Adverse events were closely followed and recorded. RESULTS: There were no significant differences in quality of preparation across the groups (80% excellent or good, 4% repreparation). Although hypocalcemia (4 of 71), hypokalemia (18 of 68), and hyperphosphatemia (39 of 69) were observed in patients receiving the tablets, no adverse events occurred. Patients preferred taking the tablets over Colyte and Fleet Phospho-Soda. CONCLUSION: The evaluation of a novel delivery system of a sodium phosphate purge is described. Intended for use before colonoscopy, it circumvents the poor taste and excessive volume of ingestion that are aversive to patients. The tableted purgative is equally effective, safe, and greatly preferred over the existing aqueous preparations. This may improve patient compliance with recommendations for screening colonoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of an instrument to assess colon cleansing
Ca, A. (1999) · The American Journal of Gastroenterology · Cited by 193
Cited by
Multitarget Stool DNA Testing for Colorectal-Cancer Screening
Imperiale, T. F., Ransohoff, D. F., Itzkowitz, S. H., Levin, T. R., Lavin, P., Lidgard, G. P., Ahlquist, D. A., & Berger, B. M. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311194 · Cited by 1,900
Lai, E. J., Calderwood, A. H., Doros, G., Fix, O. K., & Jacobson, B. C. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.05.057 · Cited by 1,314
Kaminski, M., Thomas-Gibson, S., Bugajski, M., Bretthauer, M., Rees, C., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · Endoscopy · doi:10.1055/s-0043-103411 · Cited by 885
Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia
Harewood, G. C., Sharma, V. K., & de Garmo, P. (2003) · Gastrointestinal Endoscopy · doi:10.1067/mge.2003.294 · Cited by 724
Johnson, D. A., Barkun, A. N., Cohen, L. B., Dominitz, J. A., Kaltenbach, T., Martel, M., Robertson, D. J., Boland, C. R., Giardello, F. M., Lieberman, D. A., et al. (2014) · Gastroenterology · doi:10.1053/j.gastro.2014.07.002 · Cited by 492
Metadata
- Authors
- Aronchick, C. A., Lipshutz, W. H., Wright, S. H., Dufrayne, F., & Bergman, G.
- Venue
- Gastrointestinal Endoscopy
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 52
- Issue
- 3
- Pages
- 346-352
- ISSN
- 0016-5107 (ISSN-L)
- OpenAlex
- W1995587680
- Cited by
- 390
- References
- 1
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.