CoChat

Use of two-photon light for absolute calibration of photoelectric detectors

Open access
Klyshko, D N · 1980 · Soviet Journal of Quantum Electronics
Cited by 233

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A description is given of a method for calibrating photodetectors based on some characteristics of the statistics of the field of spontaneous parametric light scattering. A phenomenological theory of parametric scattering is used to demonstrate that photons are only emitted in pairs. It is shown that, in principle, a priori information on the two-photon character and directionality of parametrically scattered light can be used for absolute calibration of photodetectors operated both in the analog linear regime and in the discrete photoelectron pulse counting regime.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1070/qe1980v010n09abeh010660

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 233

Metadata

Authors
Klyshko, D. N.
Venue
Soviet Journal of Quantum Electronics
Published
1980-09-30
Volume
10
Issue
9
Pages
1112-1117
ISSN
0049-1748 (ISSN-L)
OpenAlex
W2074940401
Cited by
233
References
1
FWCI
0.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of two-photon light for absolute calibration of photoelectric detectors. https://app.cochat.ai/papers/10.1070/qe1980v010n09abeh010660
The paper
Klyshko, D. N. (1980). Use of two-photon light for absolute calibration of photoelectric detectors. Soviet Journal of Quantum Electronics. https://doi.org/10.1070/qe1980v010n09abeh010660

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.