CoChat

Steam sterilisation’s energy and water footprint

McGain, Forbes, Moore, Graham, Black, Jim · 2017 · Australian Health Review
Cited by 61

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Objective: The aim of the present study was to quantify hospital steam steriliser resource consumption to provide baseline environmental data and identify possible efficiency gains. We sought to find the amount of steriliser electricity and water used for active cycles and for idling (standby), and the relationship between the electricity and water consumption and the mass and type of items sterilised. Methods: We logged a hospital steam steriliser’s electricity and water meters every 5 min for up to 1 year. We obtained details of all active cycles (standard 134°C and accessory or ‘test’ cycles), recording item masses and types. Relationships were investigated for both the weight and type of items sterilised with electricity and water consumption. Results: Over 304 days there were 2173 active cycles, including 1343 standard 134°C cycles that had an average load mass of 21.2 kg, with 32% of cycles <15 kg. Electricity used for active cycles was 32 652 kWh (60% of total), whereas the water used was 1 243 495 L (79%). Standby used 21 457 kWh (40%) electricity and 329 200 L (21%) water. Total electricity and water consumption per mass sterilised was 1.9 kWh kg–1 and 58 L kg–1, respectively. The linear regression model predicting electricity use was: kWh = 15.7+ 0.14 × mass (in kg; R2 = 0.58, P < 0.01). Models for water and item type were poor. Electricity and water use fell from 3 kWh kg–1 and 200 L kg–1, respectively, for 5-kg loads to 0.5 kWh kg–1 and 20 L kg–1, respectively, for 40-kg loads. Conclusions: Considerable electricity and water use occurred during standby, load mass was only moderately predictive of electricity consumption and light loads were common yet inefficient. The findings of the present study are a baseline for steam sterilisation’s environmental footprint and identify areas to improve efficiencies. What is known about the topic?: There is increasing interest in the environmental effects of healthcare. Life cycle assessment (‘cradle to grave’) provides a scientific method of analysing environmental effects. Although data of the effects of steam sterilisation are integral to the life cycles of reusable items and procedures using such items, there are few data available. Further, there is scant information regarding the efficiency of the long-term in-hospital use of sterilisers. What does this paper add?: We quantified, for the first time, long-term electricity and water use of a hospital steam steriliser. We provide useful input data for future life cycle assessments of all reusable, steam-sterilised equipment. Further, we identified opportunities for improved steriliser efficiencies, including rotating off idle sterilisers and reducing the number of light steriliser loads. Finally, others could use our methods to examine steam sterilisers and many other energy-intensive items of hospital equipment. What are the implications for practitioners?: We provide useful input data for all researchers examining the environmental footprint of reusable hospital equipment and procedures using such equipment. As a result of the present study, staff in the hospital sterile supply department have reduced steam steriliser electricity and water use considerably without impeding sterilisation throughput (and reduced time inefficiencies). Many other hospitals could benefit from similar methods to improve steam steriliser and other hospital equipment efficiencies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1071/ah15142

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 61

Metadata

Authors
McGain, F., Moore, G., & Black, J.
Venue
Australian Health Review
Published
2016-04-14
Volume
41
Issue
1
Pages
26-32
ISSN
  • 0156-5788 (ISSN-L)
  • 1449-8944
OpenAlex
W2270837100
Cited by
61
References
9
FWCI
1.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.