Cited by 144Environmental Impact and SustainabilityAnesthesia and Sedative AgentsGlobal Health and Surgery

Carbon footprint of general, regional, and combined anesthesia for total knee replacements

Open access
McGain, Forbes, Sheridan, Nicole, Wickramarachchi, Kasun, Yates, Simon, Chan, Brandon, McAlister, Scott·2021·Anesthesiology

Abstract

Background: Health care itself contributes to climate change. Anesthesia is a “carbon hotspot,” yet few data exist to compare anesthetic choices. The authors examined the carbon dioxide equivalent emissions associated with general anesthesia, spinal anesthesia, and combined (general and spinal anesthesia) during a total knee replacement. Methods: A prospective life cycle assessment of 10 patients in each of three groups undergoing knee replacements was conducted in Melbourne, Australia. The authors collected input data for anesthetic items, gases, and drugs, and electricity for patient warming and anesthetic machine. Sevoflurane or propofol was used for general anesthesia. Life cycle assessment software was used to convert inputs to their carbon footprint (in kilogram carbon dioxide equivalent emissions), with modeled international comparisons. Results: Twenty-nine patients were studied. The carbon dioxide equivalent emissions for general anesthesia were an average 14.9 (95% CI, 9.7 to 22.5) kg carbon dioxide equivalent emissions; spinal anesthesia, 16.9 (95% CI, 13.2 to 20.5) kg carbon dioxide equivalent; and for combined anesthesia, 18.5 (95% CI, 12.5 to 27.3) kg carbon dioxide equivalent. Major sources of carbon dioxide equivalent emissions across all approaches were as follows: electricity for the patient air warmer (average at least 2.5 kg carbon dioxide equivalent [20% total]), single-use items, 3.6 (general anesthesia), 3.4 (spinal), and 4.3 (combined) kg carbon dioxide equivalent emissions, respectively (approximately 25% total). For the general anesthesia and combined groups, sevoflurane contributed an average 4.7 kg carbon dioxide equivalent (35% total) and 3.1 kg carbon dioxide equivalent (19%), respectively. For spinal and combined, washing and sterilizing reusable items contributed 4.5 kg carbon dioxide equivalent (29% total) and 4.1 kg carbon dioxide equivalent (24%) emissions, respectively. Oxygen use was important to the spinal anesthetic carbon footprint (2.8 kg carbon dioxide equivalent, 18%). Modeling showed that intercountry carbon dioxide equivalent emission variability was less than intragroup variability (minimum/maximum). Conclusions: All anesthetic approaches had similar carbon footprints (desflurane and nitrous oxide were not used for general anesthesia). Rather than spinal being a default low carbon approach, several choices determine the final carbon footprint: using low-flow anesthesia/total intravenous anesthesia, reducing single-use plastics, reducing oxygen flows, and collaborating with engineers to augment energy efficiency/renewable electricity. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0000000000003967

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [8]8. Thiel CL, Eckelman MJ, Guido R, Huddleston M, Landis AE, Sherman JD, Shrake SO, Copley-Woods N, Bilec M: Environmental impacts of surgical proce- dures: Life cycle assessment of hysterectomy in the US. Environ Sci Tech 2015; 49:1779-86
  2. [42]42. Frischknecht R, Jungbluth N, Althaus H-J, Doka G, Dones R, Heck T, Hellweg S, Hischler R, Nemecek T, Rebitzer G, Spielmann M: The Ecoinvent database: Overview and methodological framework. Int J LCA 2005; 10:3-9

Cited by

Sorted by citations

Authors
McGain, F., Sheridan, N., Wickramarachchi, K., Yates, S., Chan, B., & McAlister, S.
Affiliations
  • The University of Sydney (AU)
  • Australian and New Zealand College of Anaesthetists (AU)
  • The University of Melbourne (AU)
Corresponding author
McGain, Forbes
Venue
Anesthesiology
Published
2021-09-16
Volume
135
Issue
6
Pages
976-991
ISSN
  • 0003-3022 (ISSN-L)
  • 1528-1175
OpenAlex
W3201556185
Cited by
144
References
39
Citations by year
2026: 17 · 2025: 32 · 2024: 37 · 2023: 31 · 2022: 25 · 2021: 2
FWCI
7.70
Type
journal article
Language
en
Open access
Locations
  • Anesthesiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Global Health and Surgery
Keywords
carbon footprint, total knee arthroplasty, general anesthesia, spinal anesthesia, combined anesthesia, CO2 equivalent emissions, life cycle assessment, sevoflurane, propofol, single-use medical devices, low-flow anesthesia, total intravenous anesthesia, oxygen consumption
MeSH terms
Anesthesia, Conduction, Anesthesia, General, Carbon Dioxide, Combined Modality Therapy, Humans, Nitrous Oxide, Prospective Studies, Victoria, Anesthetics, Inhalation, Arthroplasty, Replacement, Knee, Carbon Footprint

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review