Carbon footprint of general, regional, and combined anesthesia for total knee replacements
Open accessAbstract
Background: Health care itself contributes to climate change. Anesthesia is a “carbon hotspot,” yet few data exist to compare anesthetic choices. The authors examined the carbon dioxide equivalent emissions associated with general anesthesia, spinal anesthesia, and combined (general and spinal anesthesia) during a total knee replacement. Methods: A prospective life cycle assessment of 10 patients in each of three groups undergoing knee replacements was conducted in Melbourne, Australia. The authors collected input data for anesthetic items, gases, and drugs, and electricity for patient warming and anesthetic machine. Sevoflurane or propofol was used for general anesthesia. Life cycle assessment software was used to convert inputs to their carbon footprint (in kilogram carbon dioxide equivalent emissions), with modeled international comparisons. Results: Twenty-nine patients were studied. The carbon dioxide equivalent emissions for general anesthesia were an average 14.9 (95% CI, 9.7 to 22.5) kg carbon dioxide equivalent emissions; spinal anesthesia, 16.9 (95% CI, 13.2 to 20.5) kg carbon dioxide equivalent; and for combined anesthesia, 18.5 (95% CI, 12.5 to 27.3) kg carbon dioxide equivalent. Major sources of carbon dioxide equivalent emissions across all approaches were as follows: electricity for the patient air warmer (average at least 2.5 kg carbon dioxide equivalent [20% total]), single-use items, 3.6 (general anesthesia), 3.4 (spinal), and 4.3 (combined) kg carbon dioxide equivalent emissions, respectively (approximately 25% total). For the general anesthesia and combined groups, sevoflurane contributed an average 4.7 kg carbon dioxide equivalent (35% total) and 3.1 kg carbon dioxide equivalent (19%), respectively. For spinal and combined, washing and sterilizing reusable items contributed 4.5 kg carbon dioxide equivalent (29% total) and 4.1 kg carbon dioxide equivalent (24%) emissions, respectively. Oxygen use was important to the spinal anesthetic carbon footprint (2.8 kg carbon dioxide equivalent, 18%). Modeling showed that intercountry carbon dioxide equivalent emission variability was less than intragroup variability (minimum/maximum). Conclusions: All anesthetic approaches had similar carbon footprints (desflurane and nitrous oxide were not used for general anesthesia). Rather than spinal being a default low carbon approach, several choices determine the final carbon footprint: using low-flow anesthesia/total intravenous anesthesia, reducing single-use plastics, reducing oxygen flows, and collaborating with engineers to augment energy efficiency/renewable electricity. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For spinal anesthesia, emissions were mainly dominated by electricity consumption for oxygen use and cleaning reusable equipment.
“For spinal anesthesia, the emissions were mainly dominated by the electricity consumption for oxygen use and cleaning the reusable equipment.”
From A call for immediate climate action in anesthesiology: routine use of minimal or metabolic fresh gas flow reduces our ecological footprint (2023) · cites this paper as [76]
Switching from the Australian grid to the European grid decreases the carbon footprint of spinal anesthesia by 40%.
“Switching from the Australian grid (mix mainly dominated by fossil energies) to the European grid (with a larger proportion of renewable energies) decreases the carbon footprint of spinal anesthesia by 40%.76”
From A call for immediate climate action in anesthesiology: routine use of minimal or metabolic fresh gas flow reduces our ecological footprint (2023) · cites this paper as [76]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Watts, N., Amann, M., Ayeb-Karlsson, S., Belesova, K., Bouley, T., Boykoff, M., Byass, P., Cai, W., Campbell-Lendrum, D., Chambers, J., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(17)32464-9 · Cited by 1,236 · see citing works
The ecoinvent Database: Overview and Methodological Framework (7 pp)
Frischknecht, R., Jungbluth, N., Althaus, H.-J., Doka, G., Dones, R., Heck, T., Hellweg, S., Hischier, R., Nemecek, T., Rebitzer, G., et al. (2005) · The International Journal of Life Cycle Assessment · doi:10.1065/lca2004.10.181.1 · Cited by 1,114 · see citing works
Environmental impacts of the U.S. health care system and effects on public health
Eckelman, M. J., & Sherman, J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157014 · Cited by 1,017 · see citing works
MacNeill, A. J., Lillywhite, R., & Brown, C. J. (2017) · The Lancet Planetary Health · doi:10.1016/s2542-5196(17)30162-6 · Cited by 820 · see citing works
The carbon footprint of Australian health care
Malik, A., Manfred Lenzen, A., McAlister, S., & McGain, F. (2018) · The Lancet Planetary Health · doi:10.1016/s2542-5196(17)30180-8 · Cited by 539 · see citing works
Self-citationLife cycle greenhouse gas emissions of anesthetic drugs
Sherman, J., Le, C., Lamers, V., & Eckelman, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824f6940 · Cited by 496 · see citing works
Environmental sustainability in anaesthesia and critical care
McGain, F., Muret, J. C., Lawson, C., & Sherman, J. D. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.06.055 · Cited by 475 · see citing works
Self-citationThiel, C. L., Eckelman, M., Guido, R., Huddleston, M., Landis, A. E., Sherman, J., Shrake, S. O., Copley-Woods, N., & Bilec, M. M. (2015) · Environmental Science & Technology · doi:10.1021/es504719g · Cited by 416 · see citing works
Empirically based uncertainty factors for the pedigree matrix in ecoinvent
Ciroth, A., Muller, S. M., Weidema, B. P., & Lesage, P. (2013) · The International Journal of Life Cycle Assessment · doi:10.1007/s11367-013-0670-5 · Cited by 403 · see citing works
A Comparison of Reusable and Disposable Perioperative Textiles: Sustainability State-of-the-Art 2012
Overcash, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824d9cc3 · Cited by 240 · see citing works
The carbon footprint of cataract surgery
Morris, D. S., Wright, T., Somner, J. E. A., & Connor, A. (2013) · Eye · doi:10.1038/eye.2013.9 · Cited by 238 · see citing works
Assessing the Impact on Global Climate from General Anesthetic Gases
Andersen, M. P. S., Nielsen, O. J., Wallington, T. J., Karpichev, B., & Sander, S. P. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824d6150 · Cited by 230 · see citing works
Parvatker, A. G., Tunceroglu, H., Sherman, J. D., Coish, P., Anastas, P. T., Zimmerman, J. B., & Eckelman, M. J. (2019) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.8b05473 · Cited by 215 · see citing works
Comparative Life Cycle Assessment of Disposable and Reusable Laryngeal Mask Airways
Eckelman, M. J., Mosher, M., Gonzalez, A., & Sherman, J. D. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824f6959 · Cited by 213 · see citing works
Financial and environmental costs of reusable and single-use anaesthetic equipment
McGain, F., Story, D., Lim, T., & McAlister, S. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex098 · Cited by 206 · see citing works
Self-citationLife cycle costing in LCM: ambitions, opportunities, and limitations
Rebitzer, G., & Hunkeler, D. J. (2003) · The International Journal of Life Cycle Assessment · doi:10.1007/bf02978913 · Cited by 201 · see citing works
Multi-user test of the data quality matrix for product life cycle inventory data
Weidema, B. P. (1998) · The International Journal of Life Cycle Assessment · doi:10.1007/bf02979832 · Cited by 171 · see citing works
The Role of SETAC in the Development of LCA
Klöpffer, W. (2005) · The International Journal of Life Cycle Assessment · doi:10.1065/lca2006.04.019 · Cited by 162 · see citing works
Life cycle assessment perspectives on delivering an infant in the US
Campion, N., Thiel, C. L., DeBlois, J., Woods, N. C., Landis, A. E., & Bilec, M. M. (2012) · Science of The Total Environment · doi:10.1016/j.scitotenv.2012.03.006 · Cited by 144 · see citing works
A life cycle assessment of reusable and single-use central venous catheter insertion kits
McGain, F., McAlister, S., McGavin, A., & Story, D. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824e9b69 · Cited by 140 · see citing works
Self-citationThe carbon footprint of treating patients with septic shock in the intensive care unit
McGain, F., Burnham, J. P., Lau, R. H., Aye, L., Kollef, M. H., & McAlister, S. (2018) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)00970-5 · Cited by 115 · see citing works
Self-citationThe Financial and Environmental Costs of Reusable and Single-Use Plastic Anaesthetic Drug Trays
McGain, F., McAlister, S., McGavin, A., & Story, D. (2010) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1003800320 · Cited by 114 · see citing works
Self-citationAuditing Operating Room Recycling
McGain, F., Jarosz, K. M., Nguyen, M. N. H. H., Bates, S., & O’Shea, C. (2015) · A & A Case Reports · doi:10.1213/xaa.0000000000000097 · Cited by 82 · see citing works
Self-citationMcAlister, S., Ou, Y., Neff, E., Hapgood, K., Story, D., Mealey, P., & McGain, F. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-013302 · Cited by 82 · see citing works
Self-citationComparative Life Cycle Assessment of Disposable and Reusable Laryngeal Mask Airways
Eckelman, M. J., Mosher, M., Gonzalez, A., & Sherman, J. D. (2013) · Survey of Anesthesiology · doi:10.1097/01.sa.0000425549.82860.43 · Cited by 82 · see citing works
Steam sterilisation’s energy and water footprint
McGain, F., Moore, G. A., & Black, J. (2016) · Australian Health Review · doi:10.1071/ah15142 · Cited by 61 · see citing works
Self-citationMcGain, F., Story, D., Kayak, E. A., Kashima, Y., & McAlister, S. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824ddfef · Cited by 56 · see citing works
Self-citationAbandoning inhalational anaesthesia
White, S. M., & Shelton, C. L. (2020) · Anaesthesia · doi:10.1111/anae.14853 · Cited by 51 · see citing works
McGain, F., Algie, C. M., O’Toole, J., Lim, T. F., Mohebbi, M., Story, D., & Leder, K. S. (2014) · Anaesthesia · doi:10.1111/anae.12563 · Cited by 44 · see citing works
Self-citationHospital steam sterilizer usage: could we switch off to save electricity and water?
McGain, F., Moore, G. A., & Black, J. (2016) · Journal of Health Services Research & Policy · doi:10.1177/1355819615625698 · Cited by 40 · see citing works
Self-citationAllen, C., & Baxter, I. (2021) · Anaesthesia · doi:10.1111/anae.15356 · Cited by 40 · see citing works
A survey of the choice of general anaesthetic agents in Australia and New Zealand
McGain, F., Bishop, J. R., Elliot-Jones, L. M., Story, D., & Imberger, G. L. (2019) · Anaesthesia and Intensive Care · doi:10.1177/0310057x19836104 · Cited by 39 · see citing works
Self-citationZhong, G., Abbas, A., Jones, J., et al. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.07.043 · Cited by 34 · see citing works
Recycling plastics from the operating suite.
McGain, F., Clark, M., Williams, T., & Wardlaw, T. (2008) · PubMed · Cited by 32 · see citing works
Self-citationDubler, S., Zimmermann, S., Fischer, M., Schnitzler, P., Bruckner, T., Weigand, M. A., Frank, U., Hofer, S., & Heininger, A. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12768 · Cited by 32 · see citing works
Krämer, A., Kranabetter, R., Rathgeber, J., et al. (2010) · PubMed · doi:10.3205/dgkh000156 · Cited by 28 · see citing works
An Initial Evaluation of a Novel Anesthetic Scavenging Interface
Barwise, J., Lancaster, L. J., Michaels, D. R., Pope, J. E., & Berry, J. M. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31822c9a2c · Cited by 22 · see citing works
Henry, S. L., Mohan, Y., Whittaker, J., et al. (2019) · Medical Care · doi:10.1097/mlr.0000000000001191 · Cited by 16 · see citing works
Unnecessary electricity consumption by anaesthetic room monitors
Chakladar, A., & White, S. (2010) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06398.x · Cited by 6 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [8]8. Thiel CL, Eckelman MJ, Guido R, Huddleston M, Landis AE, Sherman JD, Shrake SO, Copley-Woods N, Bilec M: Environmental impacts of surgical proce- dures: Life cycle assessment of hysterectomy in the US. Environ Sci Tech 2015; 49:1779-86
- [42]42. Frischknecht R, Jungbluth N, Althaus H-J, Doka G, Dones R, Heck T, Hellweg S, Hischler R, Nemecek T, Rebitzer G, Spielmann M: The Ecoinvent database: Overview and methodological framework. Int J LCA 2005; 10:3-9
Cited by
Sorted by citations
How Ophthalmologists Can Decarbonize Eye Care
Sherry, B., Lee, S., Ramos Cadena, M. D. L. A., Laynor, G., Patel, S. R., Simon, M. D., Romanowski, E. G., Hochman, S. E., Schuman, J. S., Prescott, C., et al. (2023) · Ophthalmology · doi:10.1016/j.ophtha.2023.02.028 · Cited by 47 · see citing works
Rübsam, M.-L., Kruse, P., Dietzler, Y., Kropf, M., Bette, B., Zarbock, A., Kim, S.-C., & Hönemann, C. (2023) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-022-02393-z · Cited by 39 · see citing works
“to the European grid (with a larger proportion of renewable energies) decreases the carbon footprint of spinal anesthesia by 40%.(76) These continental differences stress the importance of defining full life-cycle assessments for different anesthetic approaches in different regions.”
Background
- Authors
- McGain, F., Sheridan, N., Wickramarachchi, K., Yates, S., Chan, B., & McAlister, S.
- Affiliations
- The University of Sydney (AU)
- Australian and New Zealand College of Anaesthetists (AU)
- The University of Melbourne (AU)
- Corresponding author
- McGain, Forbes
- Venue
- Anesthesiology
- Published
- 2021-09-16
- Volume
- 135
- Issue
- 6
- Pages
- 976-991
- ISSN
- 0003-3022 (ISSN-L)
- 1528-1175
- OpenAlex
- W3201556185
- Cited by
- 144
- References
- 39
- Citations by year
- 2026: 17 · 2025: 32 · 2024: 37 · 2023: 31 · 2022: 25 · 2021: 2
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Anesthesiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Global Health and Surgery
- Keywords
- carbon footprint, total knee arthroplasty, general anesthesia, spinal anesthesia, combined anesthesia, CO2 equivalent emissions, life cycle assessment, sevoflurane, propofol, single-use medical devices, low-flow anesthesia, total intravenous anesthesia, oxygen consumption
- MeSH terms
- Anesthesia, Conduction, Anesthesia, General, Carbon Dioxide, Combined Modality Therapy, Humans, Nitrous Oxide, Prospective Studies, Victoria, Anesthetics, Inhalation, Arthroplasty, Replacement, Knee, Carbon Footprint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review