The DOI matches its Crossref record.
Optical imaging of Renilla luciferase reporter gene expression in living mice
Open accessAbstract
Imaging reporter gene expression in living subjects is a rapidly evolving area of molecular imaging research. Studies have validated the use of reporter genes with positron emission tomography (PET), single photon emission computed tomography (SPECT), MRI, fluorescence with wild-type and mutants of green fluorescent protein, as well as bioluminescence using Firefly luciferase enzyme/protein (FL). In the current study, we validate for the first time the ability to image bioluminescence from Renilla luciferase enzyme/protein (RL) by injecting the substrate coelenterazine in living mice. A highly sensitive cooled charge-coupled device camera provides images within a few minutes of photon counting. Cells, transiently expressing the Rluc were imaged while located in the peritoneum, s.c. layer, as well as in the liver and lungs of living mice tail-vein injected with coelenterazine. Furthermore, d -luciferin (a substrate for FL) does not serve as a substrate for RL, and coelenterazine does not serve as a substrate for FL either in cell culture or in living mice. We also show that both Rluc and Fluc expression can be imaged in the same living mouse and that the kinetics of light production are distinct. The approaches validated will have direct applications to various studies where two molecular events need to be tracked, including cell trafficking of two cell populations, two gene therapy vectors, and indirect monitoring of two endogenous genes through the use of two reporter genes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Advances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870
Nanoprobes with near-infrared persistent luminescence for in vivo imaging
le Masne de Chermont, Q., Chanéac, C., Seguin, J., Pellé, F., Maîtrejean, S., Jolivet, J.-P., Gourier, D., Bessodes, M., & Scherman, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702427104 · Cited by 834
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Particulate matter and atherosclerosis: role of particle size, composition and oxidative stress
Araujo, J. A., & Nel, A. E. (2009) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-6-24 · Cited by 435
Metadata
- Authors
- Bhaumik, S., & Gambhir, S. S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-12-18
- Volume
- 99
- Issue
- 1
- Pages
- 377-382
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2068408712
- Cited by
- 536
- References
- 0
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical imaging of Renilla luciferase reporter gene expression in living mice. https://app.cochat.ai/papers/10.1073/pnas.012611099
- The paper
- Bhaumik, S., & Gambhir, S. S. (2002). Optical imaging of Renilla luciferase reporter gene expression in living mice. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.012611099
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.