The DOI matches its Crossref record.
Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution
Open accessAbstract
We show that many salient hemodynamic flow properties, which have been difficult or impossible to assess in microvessels in vivo , can be estimated by using microviscometry and fluorescent microparticle image velocimetry in microvessels >20 μm in diameter. Radial distributions in blood viscosity, shear stress, and shear rate are obtained and used to predict axial pressure gradient, apparent viscosity, and endothelial-cell surface-layer thickness in vivo . Based solely on microparticle image velocimetry data, which are readily obtainable during the course of most intravital microscopy protocols from systemically injected particle tracers, we show that the microviscometric method consistently predicted a reduction in local and apparent blood viscosity after isovolemic hemodilution. Among its clinical applications, hemodilution is a procedure that is used to treat various pathologies that require reduction in peripheral vascular-flow resistance. Our results are directly relevant in this context because they suggest that the fractional decrease in systemic hematocrit is ≈25–35% greater than the accompanying fractional decrease in microvascular-flow resistance in vivo . In terms of its fundamental usefulness, the microviscometric method provides a comprehensive quantitative analysis of microvascular hemodynamics that has applications in broad areas of medicine and physiology and is particularly relevant to quantitative studies of angiogenesis, tumor growth, leukocyte adhesion, vascular-flow resistance, tissue perfusion, and endothelial-cell mechanotransduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationMICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Reneman, R. S., Arts, T., & Hoeks, A. P. G. (2006) · Journal of Vascular Research · doi:10.1159/000091648 · Cited by 431
VEGF expression by mesenchymal stem cells contributes to angiogenesis in pancreatic carcinoma
Beckermann, B. M., Kallifatidis, G., Groth, A., Frommhold, D., Apel, A., Mattern, J., Salnikov, A. V., Moldenhauer, G., Wagner, W., Diehlmann, A., et al. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604508 · Cited by 406
Kindlin-3 is required for β2 integrin–mediated leukocyte adhesion to endothelial cells
Moser, M., Bauer, M., Schmid, S., Ruppert, R., Schmidt, S., Sixt, M., Wang, H.-V., Sperandio, M., & Fässler, R. (2009) · Nature Medicine · doi:10.1038/nm.1921 · Cited by 367
Metadata
- Authors
- Long, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-06-25
- Volume
- 101
- Issue
- 27
- Pages
- 10060-10065
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2135592952
- Cited by
- 210
- References
- 0
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution. https://app.cochat.ai/papers/10.1073/pnas.0402937101
- The paper
- Long, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R. (2004). Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0402937101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.