Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 431

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Wall Shear Stress – an Important Determinant of Endothelial Cell Function and Structure – in the Arterial System in vivo

Reneman, Robert S., Arts, Theo, Hoeks, Arnold P.G.·2006·Journal of Vascular Research

Abstract

It has been well established that wall shear stress is an important determinant of endothelial cell function and gene expression as well as of its structure. There is increasing evidence that low wall shear stress, as pres- ent in artery bifurcations opposite to the flow divider where atherosclerotic lesions preferentially originate, expresses an atherogenic endothelial gene profile. Besides, wall shear stress regulates arterial diameter by modifying the release of vasoactive mediators by endothelial cells. Most of the studies on the influence of wall shear stress on endothelial cell function and structure have been performed in vitro, generally exposing endothelial cells from different vascular regions to an average wall shear stress level calculated according to Poiseuille’s law, which does not hold for the in vivo situation, assuming wall shear stress to be constant along the arterial tree. Also in vivo wall shear stress has been determined based upon theory, assuming the velocity profile in arteries to be parabolic, which is generally not the case. Wall shear stress has been calculated, because of the lack of techniques to assess wall shear stress in vivo. In recent years, techniques have been developed to accurately assess velocity profiles in arterioles, using fluorescently labeled particles as flow tracers, and non-invasively in large arteries by means of ultrasound or magnetic resonance imaging. Wall shear rate is derived from the in vivo recorded velocity profiles and wall shear stress is estimated as the product of wall shear rate and plasma viscosity in arterioles and whole blood viscosity in large arteries. In this review, we will discuss wall shear stress in vivo, paying attention to its assessment and especially to the results obtained in both arterioles and large arteries. The limitations of the methods currently in use are discussed as well. The data obtained in the arterial system in vivo are compared with the theoretically predicted ones, and the consequences of values deviating from theory for in vitro studies are considered. Applications of wall shear stress as in flow-mediated arterial dilation, clinically in use to assess endothelial cell (dys)function, are also addressed. This review starts with some background considerations and some theoretical aspects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000091648

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 431

Metadata

Authors
Reneman, R. S., Arts, T., & Hoeks, A. P. G.
Venue
Journal of Vascular Research
Publisher
S. Karger AG
Published
2006
Volume
43
Issue
3
Pages
251-269
ISSN
  • 1018-1172 (ISSN-L)
  • 1423-0135
OpenAlex
W2022863065
Cited by
431
References
3
FWCI
17.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wall Shear Stress – an Important Determinant of Endothelial Cell Function and Structure – in the Arterial System in vivo. https://app.cochat.ai/papers/10.1159/000091648
The paper
Reneman, R. S., Arts, T., & Hoeks, A. P. G. (2006). Wall Shear Stress – an Important Determinant of Endothelial Cell Function and Structure – in the Arterial System in vivo. Journal of Vascular Research. https://doi.org/10.1159/000091648

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.