Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 482

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Serum protein markers for early detection of ovarian cancer

Open access
Mor, Gil, Visintin, Irene, Lai, Yinglei, Zhao, Hongyu, Schwartz, Peter, Rutherford, Thomas, Yue, Luo, Bray-Ward, Patricia, Ward, David C.·2005·Proceedings of the National Academy of Sciences

Abstract

Early diagnosis of epithelial ovarian cancer (EOC) would significantly decrease the morbidity and mortality from this disease but is difficult in the absence of physical symptoms. Here, we report a blood test, based on the simultaneous quantization of four analytes (leptin, prolactin, osteopontin, and insulin-like growth factor-II), that can discriminate between disease-free and EOC patients, including patients diagnosed with stage I and II disease, with high efficiency (95%). Microarray analysis was used initially to determine the levels of 169 proteins in serum from 28 healthy women, 18 women newly diagnosed with EOC, and 40 women with recurrent disease. Evaluation of proteins that showed significant differences in expression between controls and cancer patients by ELISA assays yielded the four analytes. These four proteins then were evaluated in a blind cross-validation study by using an additional 106 healthy females and 100 patients with EOC (24 stage I/II and 76 stage III/IV). Upon sample decoding, the results were analyzed by using three different classification algorithms and a binary code methodology. The four-analyte test was further validated in a blind binary code study by using 40 additional serum samples from normal and EOC cancer patients. No single protein could completely distinguish the cancer group from the healthy controls. However, the combination of the four analytes exhibited the following: sensitivity 95%, positive predictive value (PPV) 95%, specificity 95%, and negative predictive value (NPV) 94%, a considerable improvement on current methodology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0502178102

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 482

Metadata

Authors
Mor, G., Visintin, I., Lai, Y., Zhao, H., Schwartz, P., Rutherford, T., Yue, L., Bray-Ward, P., & Ward, D. C.
Venue
Proceedings of the National Academy of Sciences
Published
2005-05-12
Volume
102
Issue
21
Pages
7677-7682
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2072347219
Cited by
482
References
3
FWCI
35.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Serum protein markers for early detection of ovarian cancer. https://app.cochat.ai/papers/10.1073/pnas.0502178102
The paper
Mor, G., Visintin, I., Lai, Y., Zhao, H., Schwartz, P., Rutherford, T., Yue, L., Bray-Ward, P., & Ward, D. C. (2005). Serum protein markers for early detection of ovarian cancer. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0502178102

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.