Volumetric tomography of fluorescent proteins through small animals in vivo
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Volumetric detection and accurate quantification of fluorescent proteins in entire animals would greatly enhance our ability to monitor biological processes in vivo . Here we present a quantitative tomographic technique for visualization of superficial and deep-seated (>2–3 mm) fluorescent protein activity in vivo . We demonstrate noninvasive imaging of lung tumor progression in a murine model, as well as imaging of gene delivery using a herpes virus vector. This technology can significantly improve imaging capacity over the current state of the art and should find wide in vivo imaging applications in drug discovery, immunology, and cancer research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Cited by
Imaging in the era of molecular oncology
Weissleder, R., & Pittet, M. J. (2008) · Nature · doi:10.1038/nature06917 · Cited by 2,364
Self-citationTransparent Adult Zebrafish as a Tool for In Vivo Transplantation Analysis
White, R. M., Sessa, A., Burke, C., Bowman, T., LeBlanc, J., Ceol, C., Bourque, C., Dovey, M., Goessling, W., Burns, C. E., et al. (2008) · Cell Stem Cell · doi:10.1016/j.stem.2007.11.002 · Cited by 1,408
Scale: a chemical approach for fluorescence imaging and reconstruction of transparent mouse brain
Hama, H., Kurokawa, H., Kawano, H., Ando, R., Shimogori, T., Noda, H., Fukami, K., Sakaue-Sawano, A., & Miyawaki, A. (2011) · Nature Neuroscience · doi:10.1038/nn.2928 · Cited by 1,142
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Self-citationDehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Metadata
- Authors
- Zacharakis, G., Kambara, H., Shih, H., Ripoll, J., Grimm, J., Saeki, Y., Weissleder, R., & Ntziachristos, V.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-12-12
- Volume
- 102
- Issue
- 51
- Pages
- 18252-18257
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2080647067
- Cited by
- 118
- References
- 2
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetric tomography of fluorescent proteins through small animals in vivo. https://app.cochat.ai/papers/10.1073/pnas.0504628102
- The paper
- Zacharakis, G., Kambara, H., Shih, H., Ripoll, J., Grimm, J., Saeki, Y., Weissleder, R., & Ntziachristos, V. (2005). Volumetric tomography of fluorescent proteins through small animals in vivo. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0504628102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.