The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
FLUORESCENCE MOLECULAR IMAGING
Abstract
There is a wealth of new fluorescent reporter technologies for tagging of many cellular and subcellular processes in vivo. This imposed contrast is now captured with an increasing number of available imaging methods that offer new ways to visualize and quantify fluorescent markers distributed in tissues. This is an evolving field of imaging sciences that has already achieved major advances but is also facing important challenges. It is nevertheless well poised to significantly impact the ways of biological research, drug discovery, and clinical practice in the years to come. Herein, the most pertinent technologies associated with in vivo noninvasive or minimally invasive fluorescence imaging of tissues are summarized. Focus is given to small-animal imaging. However, while a broad spectrum of fluorescence reporter technologies and imaging methods are outlined, as necessary for biomedical research, and clinical translation as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Controlling waves in space and time for imaging and focusing in complex media
Mosk, A. P., Lagendijk, A., Lerosey, G., & Fink, M. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.88 · Cited by 1,536
Nanoprobes with near-infrared persistent luminescence for in vivo imaging
le Masne de Chermont, Q., Chanéac, C., Seguin, J., Pellé, F., Maîtrejean, S., Jolivet, J.-P., Gourier, D., Bessodes, M., & Scherman, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702427104 · Cited by 834
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Rational Design of Molecular Fluorophores for Biological Imaging in the NIR‐II Window
Yang, Q., Ma, Z., Wang, H., Zhou, B., Zhu, S., Zhong, Y., Wang, J., Wan, H., Antaris, A., Ma, R., et al. (2017) · Advanced Materials · doi:10.1002/adma.201605497 · Cited by 467
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Metadata
- Authors
- Ntziachristos, V.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2006-08-01
- Volume
- 8
- Issue
- 1
- Pages
- 1-33
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2149262494
- Cited by
- 731
- References
- 1
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FLUORESCENCE MOLECULAR IMAGING. https://app.cochat.ai/papers/10.1146/annurev.bioeng.8.061505.095831
- The paper
- Ntziachristos, V. (2006). FLUORESCENCE MOLECULAR IMAGING. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev.bioeng.8.061505.095831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.