Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 589

The DOI matches its Crossref record.

X-ray damage to the Mn 4 Ca complex in single crystals of photosystem II: A case study for metalloprotein crystallography

Open access
Yano, Junko, Kern, Jan, Irrgang, Klaus-Dieter, Latimer, Matthew J., Bergmann, Uwe, Glatzel, Pieter, Pushkar, Yulia, Biesiadka, Jacek, Loll, Bernhard, Sauer, Kenneth, Messinger, Johannes, Zouni, Athina, Yachandra, Vittal K.·2005·Proceedings of the National Academy of Sciences

Abstract

X-ray absorption spectroscopy was used to measure the damage caused by exposure to x-rays to the Mn 4 Ca active site in single crystals of photosystem II as a function of dose and energy of x-rays, temperature, and time. These studies reveal that the conditions used for structure determination by x-ray crystallography cause serious damage specifically to the metal-site structure. The x-ray absorption spectra show that the structure changes from one that is characteristic of a high-valent Mn 4 (III 2 ,IV 2 ) oxo-bridged Mn 4 Ca cluster to that of Mn(II) in aqueous solution. This damage to the metal site occurs at a dose that is more than one order of magnitude lower than the dose that results in loss of diffractivity and is commonly considered safe for protein crystallography. These results establish quantitative x-ray dose parameters that are applicable to redox-active metalloproteins. This case study shows that a careful evaluation of the structural intactness of the active site(s) by spectroscopic techniques can validate structures derived from crystallography and that it can be a valuable complementary method before structure–function correlations of metalloproteins can be made on the basis of high-resolution x-ray crystal structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0505207102

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 589

Metadata

Authors
Yano, J., Kern, J., Irrgang, K.-D., Latimer, M. J., Bergmann, U., Glatzel, P., Pushkar, Y., Biesiadka, J., Loll, B., Sauer, K., Messinger, J., Zouni, A., & Yachandra, V. K.
Venue
Proceedings of the National Academy of Sciences
Published
2005-08-15
Volume
102
Issue
34
Pages
12047-12052
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2033285121
Cited by
589
References
0
FWCI
23.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: X-ray damage to the Mn 4 Ca complex in single crystals of photosystem II: A case study for metalloprotein crystallography. https://app.cochat.ai/papers/10.1073/pnas.0505207102
The paper
Yano, J., Kern, J., Irrgang, K.-D., Latimer, M. J., Bergmann, U., Glatzel, P., Pushkar, Y., Biesiadka, J., Loll, B., Sauer, K., Messinger, J., Zouni, A., & Yachandra, V. K. (2005). X-ray damage to the Mn 4 Ca complex in single crystals of photosystem II: A case study for metalloprotein crystallography. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0505207102

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.