The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dynamic force spectroscopy of parallel individual Mucin1–antibody bonds
Open accessAbstract
We used atomic force microscopy to measure the binding forces between Mucin1 (MUC1) peptide and a single-chain variable fragment (scFv) antibody selected from a scFv library screened against MUC1. This binding interaction is central to the design of molecules used for targeted delivery of radioimmunotherapeutic agents for prostate and breast cancer treatment. Our experiments separated the specific binding interaction from nonspecific interactions by tethering the antibody and MUC1 molecules to the atomic force microscope tip and sample surface with flexible polymer spacers. Rupture force magnitude and elastic characteristics of the spacers allowed identification of the rupture events corresponding to different numbers of interacting proteins. We used dynamic force spectroscopy to estimate the intermolecular potential widths and equivalent thermodynamic off rates for monovalent, bivalent, and trivalent interactions. Measured interaction potential parameters agree with the results of molecular docking simulation. Our results demonstrate that an increase of the interaction valency leads to a precipitous decline in the dissociation rate. Binding forces measured for monovalent and multivalent interactions match the predictions of a Markovian model for the strength of multiple uncorrelated bonds in a parallel configuration. Our approach is promising for comparison of the specific effects of molecular modifications as well as for determination of the best configuration of antibody-based multivalent targeting agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Cited by
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Single-molecule experiments in biological physics: methods and applications
Ritort, F. (2006) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/18/32/r01 · Cited by 393
Interpreting the widespread nonlinear force spectra of intermolecular bonds
Friddle, R. W., Noy, A., & De Yoreo, J. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202946109 · Cited by 297
Self-citationApplications of biosensing atomic force microscopy in monitoring drug and nanoparticle delivery
Lamprecht, C., Hinterdorfer, P., & Ebner, A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.917078 · Cited by 46
Metadata
- Authors
- Sulchek, T. A., Friddle, R. W., Langry, K., Lau, E. Y., Albrecht, H., Ratto, T. V., DeNardo, S. J., Colvin, M. E., & Noy, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-11-03
- Volume
- 102
- Issue
- 46
- Pages
- 16638-16643
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2004533106
- Cited by
- 175
- References
- 1
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic force spectroscopy of parallel individual Mucin1–antibody bonds. https://app.cochat.ai/papers/10.1073/pnas.0505208102
- The paper
- Sulchek, T. A., Friddle, R. W., Langry, K., Lau, E. Y., Albrecht, H., Ratto, T. V., DeNardo, S. J., Colvin, M. E., & Noy, A. (2005). Dynamic force spectroscopy of parallel individual Mucin1–antibody bonds. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0505208102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.