The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Marker-specific sorting of rare cells using dielectrophoresis
Open accessAbstract
Current techniques in high-speed cell sorting are limited by the inherent coupling among three competing parameters of performance: throughput, purity, and rare cell recovery. Microfluidics provides an alternate strategy to decouple these parameters through the use of arrayed devices that operate in parallel. To efficiently isolate rare cells from complex mixtures, an electrokinetic sorting methodology was developed that exploits dielectrophoresis (DEP) in microfluidic channels. In this approach, the dielectrophoretic amplitude response of rare target cells is modulated by labeling cells with particles that differ in polarization response. Cell mixtures were interrogated in the DEP-activated cell sorter in a continuous-flow manner, wherein the electric fields were engineered to achieve efficient separation between the dielectrophoretically labeled and unlabeled cells. To demonstrate the efficiency of marker-specific cell separation, DEP-activated cell sorting (DACS) was applied for affinity-based enrichment of rare bacteria expressing a specific surface marker from an excess of nontarget bacteria that do not express this marker. Rare target cells were enriched by >200-fold in a single round of sorting at a single-channel throughput of 10,000 cells per second. DACS offers the potential for automated, surface marker-specific cell sorting in a disposable format that is capable of simultaneously achieving high throughput, purity, and rare cell recovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guzman, L. M., Belin, D., Carson, M. J., & Beckwith, J. (1995) · Journal of Bacteriology · doi:10.1128/jb.177.14.4121-4130.1995 · Cited by 4,935
Analysis of gene control signals by DNA fusion and cloning in Escherichia coli
Casadaban, M. J., & Cohen, S. N. (1980) · Journal of Molecular Biology · doi:10.1016/0022-2836(80)90283-1 · Cited by 2,477
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Dielectrophoresis: The Behavior of Neutral Matter in Nonuniform Electric Fields
Pohl, H. A. (1978) · Medical Entomology and Zoology · Cited by 935
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Microfluidic sorting of mammalian cells by optical force switching
Wang, M. M., Tu, E., Raymond, D. E., Yang, J. M., Zhang, H., Hagen, N., Dees, B., Mercer, E. M., Forster, A. H., Kariv, I., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1050 · Cited by 690
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Georgiou, G., Stathopoulos, C., Daugherty, P. S., Nayak, A. R., Iverson, B. L., & III, R. C. (1997) · Nature Biotechnology · doi:10.1038/nbt0197-29 · Cited by 519
Self-citationDielectrophoretic Sorting of Particles and Cells in a Microsystem
Fiedler, S., Shirley, S. G., Schnelle, T., & Fuhr, G. (1998) · Analytical Chemistry · doi:10.1021/ac971063b · Cited by 432
Shizuru, J. A., Negrin, R. S., & Weissman, I. L. (2005) · Annual Review of Medicine · doi:10.1146/annurev.med.54.101601.152334 · Cited by 339
Gross, H. J., Verwer, B., Houck, D., Hoffman, R. A., & Recktenwald, D. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.2.537 · Cited by 198
High-speed cell sorting: fundamentals and recent advances
Ibrahim, S. F., & van den Engh, G. (2003) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00009-5 · Cited by 185
Rapid isolation of high-affinity protein binding peptides using bacterial display
Bessette, P. H., Rice, J. J., & Daugherty, P. S. (2004) · Protein Engineering Design and Selection · doi:10.1093/protein/gzh084 · Cited by 155
Self-citationFlow Through, Immunomagnetic Cell Separation
Chalmers, J. J., Zborowski, M., Sun, L., et al. (1998) · Biotechnology Progress · doi:10.1021/bp970140l · Cited by 132
Immunomagnetic cell sorting—pushing the limits
Thiel, A., Scheffold, A., & Radbruch, A. (1998) · Immunotechnology · doi:10.1016/s1380-2933(98)00010-4 · Cited by 114
The potential of dielectrophoresis for single-cell experiments
Müller, T., Pfennig, A., Klein, P., Gradl, G., Jäger, M. S., & Schnelle, T. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1266047 · Cited by 104
Commercial high speed machines open new opportunities in high throughput flow cytometry (HTFC)
Ashcroft, R. G., & Lopez, P. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00219-2 · Cited by 77
Tissue engineering with mesenchymal stem cells
Kuo, C. K., & Tuan, R. S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1256272 · Cited by 61
Wachtel, S. S., Shulman, L., & Sammons, D. W. (2001) · Clinical Genetics · doi:10.1034/j.1399-0004.2001.590202.x · Cited by 34
Cited by
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Metadata
- Authors
- Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-10-18
- Volume
- 102
- Issue
- 44
- Pages
- 15757-15761
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1972783166
- Cited by
- 428
- References
- 20
- FWCI
- 18.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.