The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Light-switching excimer probes for rapid protein monitoring in complex biological fluids
Open accessAbstract
Quantitative protein bioanalysis in complex biological fluids presents considerable challenges in biological studies and disease diagnosis. The major obstacles are the background signals from both the probe and the biological fluids where the proteins reside. We have molecularly engineered light-switching excimer aptamer probes for rapid and sensitive detection of a biomarker protein, platelet-derived growth factor (PDGF). Labeled with one pyrene at each end, the aptamer switches its fluorescence emission from ≈400 nm (pyrene monomer) to 485 nm (pyrene excimer) upon PDGF binding. This fluorescence wavelength change from monomer to excimer emission is a result of aptamer conformation rearrangement induced by target binding. The excimer probe is able to effectively detect picomolar PDGF in homogeneous solutions. Because the excimer has a much longer fluorescence lifetime (≈40 ns) than that of the background (≈5 ns), time-resolved measurements were used to eliminate the biological background. We thus were able to detect PDGF in a cell sample quantitatively without any sample pretreatment. This molecular engineering strategy can be used to develop other aptamer probes for protein monitoring. Combined with lifetime-based measurements and molecular engineering, light-switching excimer aptamer probes hold great potential in protein analysis for biomedical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
In vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,772
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Photophysics of aromatic molecules
Birks, J. B. (1970) · Cited by 3,363
Photophysics of preassociated pyrenes in aqueous polymer solutions and in other organized media
Winnik, F. M. (1993) · Chemical Reviews · doi:10.1021/cr00018a001 · Cited by 1,786
Selection in vitro of an RNA enzyme that specifically cleaves single-stranded DNA
Robertson, D. L., & Joyce, G. F. (1990) · Nature · doi:10.1038/344467a0 · Cited by 1,331
Structure-Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028962o · Cited by 1,040
Tyers, M., & Mann, M. (2003) · Nature · doi:10.1038/nature01510 · Cited by 1,006
Proteomic applications for the early detection of cancer
Wulfkuhle, J. D., Liotta, L. A., & Petricoin, E. F. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1043 · Cited by 907
Hanash, S. (2003) · Nature · doi:10.1038/nature01514 · Cited by 900
Pagano, R. E., Martin, O. C., Kang, H. C., & Haugland, R. P. (1991) · The Journal of cell biology · doi:10.1083/jcb.113.6.1267 · Cited by 491
In Vitro Selection of Structure‐Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200461848 · Cited by 455
Automated selection of anti-Protein aptamers
Cox, J. C., & Ellington, A. D. (2001) · Bioorganic & Medicinal Chemistry · doi:10.1016/s0968-0896(01)00028-1 · Cited by 427
Inhibitory DNA Ligands to Platelet-Derived Growth Factor B-Chain
Green, L. S., Jellinek, D., Jenison, R., Östman, A., Heldin, C.-H., & Janjic, N. (1996) · Biochemistry · doi:10.1021/bi961544+ · Cited by 390
Programmable ligand-controlled riboregulators of eukaryotic gene expression
Bayer, T. S., & Smolke, C. D. (2005) · Nature Biotechnology · doi:10.1038/nbt1069 · Cited by 376
Molecular Aptamer Beacons for Real-Time Protein Recognition
Li, J. J., Fang, X., & Tan, W. (2002) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2002.6581 · Cited by 294
Self-citationNutiu, R., & Li, Y. (2004) · Chemistry – A European Journal · doi:10.1002/chem.200305470 · Cited by 291
In vitro selection of signaling aptamers
Jhaveri, S., Rajendran, M., & Ellington, A. D. (2000) · Nature Biotechnology · doi:10.1038/82414 · Cited by 240
Unambiguous Detection of Target DNAs by Excimer−Monomer Switching Molecular Beacons
Fujimoto, K., Shimizu, H., & Inouye, M. (2004) · The Journal of Organic Chemistry · doi:10.1021/jo049824f · Cited by 175
Fang, X., Sen, A., Vicens, M., & Tan, W. (2003) · ChemBioChem · doi:10.1002/cbic.200300615 · Cited by 168
Self-citationMasuko, M., Ohtani, H., Ebata, K., & Shimadzu, A. (1998) · Nucleic Acids Research · doi:10.1093/nar/26.23.5409 · Cited by 122
Physical and Photophysical Characterization of a BODIPY Phosphatidylcholine as a Membrane Probe
Dahim, M., Mizuno, N. K., Li, X., Momsen, W. E., Momsen, M. M., & Brockman, H. L. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73921-0 · Cited by 85
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Aptamers evolved from live cells as effective molecular probes for cancer study
Shangguan, D., Li, Y., Tang, Z., Cao, Z. C., Chen, H. W., Mallikaratchy, P., Sefah, K., Yang, C. J., & Tan, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602615103 · Cited by 1,516
Self-citationSong, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Metadata
- Authors
- Yang, C. J., Jockusch, S., Vicens, M., Turro, N. J., & Tan, W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-11-21
- Volume
- 102
- Issue
- 48
- Pages
- 17278-17283
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2165116615
- Cited by
- 337
- References
- 25
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.